background image

OWNER’S INFO

Owner’s Information

ON

OFF

Manual On/Off Switch

Lighting, Operation and Rating Information

The Lighting, Operation and Rating information is 
located on a plate under the burner. To access the 
plate, remove the fret or access panel, grab the plate 
and take it out to read it. There is important information 
on both sides of the plate.

Servicing

If any attention is required for your appliance, contact 
your supplier quoting the model number. It will be helpful 
if the appliance’s serial number can also be quoted. This 
number is on the rating plate, which is located under the 
burner. The replacement parts are shown at the end of 
this manual. Please always quote the part number and 
description when requesting spare parts.

Fireplace Control Devices

There are three ways to control your 

fi

 replace.

1.  Thermostatic Remote Control;
2.  Wall Switch (optional);
3.  Manual On/Off Switch.

The manual On/Off switch must be ON for the 

fi

 replace 

to function. It can be used to shut off the 

fi

 replace in 

case of emergency—see next sub-section.
The Thermostatic Remote Control can be programmed 
to function automatically—see pages 24–27.
The Wall Switch (optional) can be used to turn on, off 
and to increase or decrease the 

fl

 ame height—see 

1265WSK—Wall Switch Kit.

NOTE:

 The remote control in the AUTO mode will 

override the wall switch.

WARNING

DO NOT ATTEMPT TO TOUCH THE DATA PLATE 
WHILE THE FIREPLACE IS STILL HOT! 

Let the 

fi

 replace cool 

fi

 rst before touching it.

How to Turn Your Fireplace OFF 

(including pilot)

Familiarize yourself with each of these methods before 
operating your 

fi

 replace.

Handset and Wall Switch:

 Press and hold the OFF 

button for a second. 
If the 

fl

 ames are on, they go down and you hear the 

valve motor wind down. You hear a clunk and a beep 
indicating that the valve has received the signal from 
the remote control.

Manual ON/OFF Switch:

 Press the 

O

 button.

How to Ensure Your Fireplace Cannot 
Be Turned ON Inadvertently

You can use one of the two following methods to 
ensure that your 

fi

 replace will not turn on when you 

don’t want it on. 

First, ensure your fi replace is turned off—including 
the pilot—and cold BEFORE going ahead.

Remove all batteries from the receiver as well as the 
battery from the handset.
Alternately, you can prevent your 

fi

 replace from lighting 

by pressing the 

button on the manual ON/OFF switch 

on the gas valve—see image above.

Automatic Shut-Off 

(in certain conditions)

Your 

fi

 replace’s remote control is equipped with an 

automatic shut-off mechanism which is activated in 
certain conditions. See page 27 in the 

Remote Control 

Operation 

section for a description of this feature.

ON

OFF

Wall Switch 
(optional)

Manual On/Off Switch

Thermostatic Remote 
Control

Wall Switch

(optional)

Remote control 

handset

23

Summary of Contents for 739IRN

Page 1: ...tified kit is used This appliance is a domestic room heating appliance It must not be used for any other purposes such as drying clothes etc This appliance is suitable for installation in a bedroom or...

Page 2: ...l your dealer immediately Do not try to repair the unit as you may cause an injury or damage the fireplace The information contained in this installation manual is believed to be correct at the time o...

Page 3: ...contact with a hot surface A physical barrier is strongly recommended if there are young children or at risk individuals in the house Install an approved after market safety gate to keep toddlers youn...

Page 4: ...s Installation 15 Ceramic Enamel Panels Installation 16 Ceramic Rocks Installation 17 Window Refitting 19 Remote Control Initial Set up 19 Operation Check Aeration Settings Adjustment 20 Remote Contro...

Page 5: ...per operation Due to the high temperature the appliance should be LOCATED out of traffic areas and away from furniture and draperies Clothing or flammable material SHOULD NOT BE PLACED on or near the...

Page 6: ...ce with the current ANSI Z223 1 and or local codes having jurisdiction Heating value of gas in some areas is reduced to compensate for elevation consult your local gas utility to confirm For installat...

Page 7: ...NOT install into combustible construction This appliance is NOT APPROVED for installation with a zero clearance kit 739IR fireplace Chimney Terminal Cap Flashing Existing unaltered functioning solid...

Page 8: ...lectrical inlet Optional Outer Trim or Surround sold separately X Y INSTALLATION Dimensions Cavity Check that masonry step does not interfere with install dimensions or vent pipe If mantel is combusti...

Page 9: ...de of the mantel to finished hearth or surface that the unit is sitting on Finishing Materials Combustible materials Material such as wood compressed paper plant fibers plastics or any material capabl...

Page 10: ...vertical vent termination Venting Table Maximum vertical height 40 ft measured to bottom of termination Minimum vertical height 10 ft measured to bottom of termination Maximum horizontal run 4 ft meas...

Page 11: ...rything 4 Clean cavity chimney ash dump and clean out 5 Install venting pipes 6 Attach conversion plate to existing fireplace 7 Install and test blower if used 8 Fit appliance into cavity 9 Connect an...

Page 12: ...drill an access hole of 1 5 inch 38 mm or less through the lower sides or bottom of the firebox The access hole must be plugged with non combustible insulation after the gas supply line has been inst...

Page 13: ...me 3 Set the window aside in a safe place to avoid damage Fan installation If the 755CFK Circulating Fan Kit blower is to be installed we suggest that you do it now The fan cavity is accessible from t...

Page 14: ...t the two liners ensuring that the exhaust liner is connected to the identified EXHAUST vent collar Secure with 4 tapping screws per liner If the vent slider was removed from the firebox slide the fir...

Page 15: ...ting of that system at test pressures in excess of 1 2 psig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its equipment shut off valve during any pressure testing...

Page 16: ...st the back of the firebox on the ledge at bottom 3 Rotate the anchor up and out of the way and slide the left hand side panel against the firebox side The panel should be parallel to the edge of the...

Page 17: ...platform in the firebox rotating down to insert the front first behind the Front Support Lay the back of the ceramic platform against the rear ceramic panel again being careful not to scrape the ceram...

Page 18: ...third rocks from the left rest its end on the glass near the edge of the platform as shown Make sure to leave a gap between the twig and the first rock to allow flame to come up between the twig and...

Page 19: ...o bed in the window seal Remote Control Initial Set up The receiver and the handset of the remote control sys tem must be initially synchronized before the first use 1 Insert alkaline batteries in the...

Page 20: ...it We also advise that the handset should be located away from any other heat source and not in direct sunlight as this may affect the temperature sensor located in the remote handset Operation Check...

Page 21: ...the ceramic glass Any abrasion of the surface has the immediate effect of compromising the strength of the glass An emulsion type cleaner is recommended Use a soft damp cloth to apply the cleaner Dry...

Page 22: ...pt clear and free from combustible materials gasoline and other flammable vapors and liquids Inspect the vent terminal outdoors regularly to make sure that snow trees bushes leaves or other objects do...

Page 23: ...ntrol in the AUTO mode will override the wall switch WARNING DO NOT ATTEMPT TO TOUCH THE DATA PLATE WHILE THE FIREPLACE IS STILL HOT Let the fireplace cool first before touching it How to Turn Your Fi...

Page 24: ...otor turns automatically to maximum flame height 1 Make sure that the MAN knob on the valve is in ON position 2 Make sure that the switch on the valve is in the I position 3 Press and hold the OFF and...

Page 25: ...Mode Sun Moon TEMP Daytime temperature setting Nighttime temperature setting TIMER Start time setting Stop time setting Flame Height The flame height can be adjusted in the following manners In MANUAL...

Page 26: ...before you get up P1 start time and to turn off when you leave for the day P1 stop time Then you can set your fireplace to turn on again at the end of the day P2 start time and to turn off when you go...

Page 27: ...This does not happen when the power supply is interrupted Handset Receiver Match The remote control handset and receiver are programmed to function together In case of a replacement of the handset or...

Page 28: ...GLQJ QHDU WKH RRr If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMA7 1 7 21 J RFDWH WKH SLORW J LQVLGH RI UHER DW HIW DQG...

Page 29: ...Optional Wall Switch Kit 1265WSK Connector Red Yellow GV60 Wiring Diagram INSTALLATION Wiring Diagram 29...

Page 30: ...onnector 46DVA ADF Co axial to Co linear Adapter 46DVA GCL TM 4CAA 556CLA Co linear to Co axial Adapter 46DVA GK TM 4CTA Aluminum Flexible Liner 3 diameter 2280 Series 3 ACFL NOTE 2 ply liner approved...

Page 31: ...tion for air from other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards i This warranty does no...

Page 32: ...Burner Tray 4001676 30 Pipe Valve to Main Burner incl olive nuts 4000065 31 Burner Plate Access Panel 4001680 32 Module Gasket Rear 4000175 33 Module Gasket Right 4000174 34 Module Gasket Front 400017...

Page 33: ...5 21 22 23 24 19 OWNER S INFO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 44 43 45 14a NG LPG 13a 47 48 49 50 51 52 53 49a 55 56 57 58 59 60 61 54 62 6...

Page 34: ...39IR NG natural gas LPG propane Serial No Front Trim code description e g 743FVI Double Door FenderFire Purchase date mm dd yyyy Home Owner Name Address City Province State Postal Code Zip Phone Email...

Page 35: ...hut Thank you for choosing a Valor Product Postage needed Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty registration at www valorfireplace...

Reviews: