14
Do not remove the window when the appliance is hot. Not only is it dangerous but it
could cause damage to the gasket.
Appliance Preparation
9.1 Window Removal
At the bottom corners of the window, turn the two spring-loaded bolts 90
degrees to release the window from the
fi
rebox.
Pull the bottom of the window away from the
fi
rebox while lifting it
off the top rail.
Carefully lift the window away and put aside in a safe location to
avoid damage.
When reinstalling, follow the instructions from the section Window
Re
fi
tting on page 20.
9.2 Ignition Spark Check
The pilot burner and electrode unit are at the left end of the burner.
Push in the lighting knob and turn it counter-clockwise through the “IGN”
position to “PILOT”. A spark should
fl
ash across from the pilot electrode to the
pilot burner shield as shown below.
•
•
•
•
CAUTION: Do not abuse the appliance’s glass by striking, slamming or similar trauma.
Do not use the appliance with the window removed, glass panel cracked or broken.
Only use glass approved for use with this heater. Do not use substitute materials.
Replacement of the panel should only be carried out by a licensed quali
fi
ed service
person.
Thermostat Knob
Gas Control Knob
Spring-loaded bolts
1
2
f i r e - p a r t s . c o m