Replacement Parts

Key

Description

Part no.

1

Outer vent collar

330A888

2

Blanking plate

330A964

3

Side frame 

fi

 xing brackets (2)

3000255

4

Rear log support

4001999

4a

Rear log support spacers (2)

4002870

5

Burner module NG

4001952

Burner module LPG

4001953

6

Window assembly

3000389S

7

Window baf

fl

 e

4001970

8

Restrictor plates (2)

4002895

9

Adjustable plates (2)

4002896

Screws (2) (not shown)

100A757

11a Flashback shield LPG

3000371

11b Air shutter cover NG

4002346

12a Air shutter slider LPG

320B293

12b Air shutter slider NG

4002345

13

Burner NG

740K189

Burner LPG

740K190

14

Injector elbow 82-650 NG

9730012

Injector elbow 92-260 LPG

9730007

15

Burner mounts (2)

4001964

16

Front log supports (2)

4001965

17

Pilot assembly NG

4000062S

Pilot assembly LPG

4000063S

18

Pilot bracket

720A542

19

Pilot injector no. 35 NG

4002511

Pilot injector no. 27 LPG

720A195

20

Hooked olive for pilot injector

720A196

21

Olive nut for pilot pipe

420K385

22

Electrode

720A543

23

Electrode retaining nut

720A200

24

Thermocouple

4000061

25

Pipe—valve to pilot

030A226

26

Olive nut for pilot pipe

220K913

27

Pilot shield

4002203

28

Pilot support bracket

330A904

29

Pilot seal

620B995

30

Access plate

4001680

31

Pipe—valve to main burner

3000247

32

Burner plate

4001966

33

Gaskets—module plate sides (2)

3000399

34

Gaskets—module plate front & back

3000400

35

Valve mounting bracket

4000141

36

Thermocurrent interruptor

4001037

Key

Description

Part no.

37

Valve GV60 no. 125 by-pass screw

4000873

38

Inlet brass connector

4000746

39

Valve to main burner pipe connector

220K891

40

GV60 Valve assembly

4000873X

41

Ignition cable 500 mm

4001039

41a Ignition cable sleeve

4002244

42

Cable interruptor

4001035

43

Handset wall holder

9000008

44

Wiring harness

4001187

45

Remote control handset

4001910

46

Remote control receiver

4001911

47

Wall switch kit

1265WSK

48

Liner panels—complete set

a

Enamel black

618EBL

b

Ceramic 

fl

 uted black

620FBL

c

Valor red brick

621VRL

d

Ledgestone

622LSL

49

Rear panel

a

Enamel black

4002085

b

Ceramic 

fl

 uted black

4002109

c

Valor red brick

4002105

d

Ledgestone

4002113

50

Left side panel

a

Enamel black

4002087

b

Ceramic 

fl

 uted black

4002107

c

Valor red brick

4002103

d

Ledgestone

4002111

51

Right side panel

a

Enamel black

4002086

b

Ceramic 

fl

 uted black

4002108

c

Valor red brick

4002104

d

Ledgestone

4002112

52

Top panel

a

Ceramic plain black

4002110

b

Ceramic plain black

4002110

c

Valor red brick

4002106

d

Ledgestone

4002114

53

Log set complete

4001696

54

Rear log

4001697

55

Front left log

4001699

56

Front right log

4001700

57

Right cross log

4001701

58

Middle cross log

4001698

59

Left cross log

4001772

60

12-inch Top stand-off

4002121

Summary of Contents for 650ILN

Page 1: ...any other purposes such as drying clothes etc This appliance is suitable for installation in a bedroom or bed sitting room Manufactured by MILES INDUSTRIES LTD British Columbia Canada www valorfirepla...

Page 2: ...by a qualified dealer Each Valor fireplace is fully tested during the production process for your safety and comfort Your unit has been professionally installed by Dealer Name _______________________...

Page 3: ...22 Liner Panels Installation 23 Ceramic Logs Installation 24 Window Refitting Baffle Installation 25 Wall Switch Kit Installation 26 Remote Control Initial Set up 27 Operation Check Aeration Settings...

Page 4: ...OBSTRUCT the flow of combustion and ventilation air Keep the front of the appliance CLEAR of all obstacles and materials for servicing and proper operation Due to the high temperature the appliance s...

Page 5: ...ch additional level of the dwelling building or structure served by the side wall horizontal vented gas fueled equipment It shall be the responsibility of the property owner to secure the services of...

Page 6: ...facturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases but identifies special venting systems the following requirement...

Page 7: ...al and or local authorities having jurisdiction Model 650ILN 650ILP Gas Natural Propane Altitude Ft 0 4 500 Input Max Btu h 24 000 24 000 Input Min Btu h 6 500 13 000 Manifold pressure in w c 3 95 10...

Page 8: ...le from top to rear outlet Framing See Framing section Remote Handset Wall Holder Wall Finish May be combustible material NOTE Finished wall surface including tiles etc MUST be minimum 3 4 19 mm set b...

Page 9: ...406 mm 26 3 4 679 mm 38 5 8 981 mm 32 3 16 817 mm 29 3 4 756 mm 30 3 4 781 mm 3 76 mm min To side wall from inner frame in front of the appliance 8 1 4 210 mm From finished wall surface to top vent MI...

Page 10: ...ear vent with rise MINIMUM 1 2 13 mm space between bottom of backing plate and surface of hearth or floor finish in front for air flow Combustible framing allowed beneath fireplace When the appliance...

Page 11: ...ess A non combustible wall can be of any thickness up to the maximum horizontal run of vent pipe allowed for the particular installation 10 254 mm 10 254 mm Align the vent center to the center of the...

Page 12: ...WALL THIMBLE PIPE LENGTH PIPE LENGTH PIPE LENGTH 817VAK 817VAK PIPE LENGTH 90 ELBOW CEILING FIRESTOP ATTIC FIRESTOP ATTIC INSULATION SHIELD FLASHING STORM COLLAR VERTICAL TERMINATION Typical Co Axial...

Page 13: ...ling the joints between the outer vent tube and the inner and outer wall plates We recommend the use of a high quality polyurethane sealant Co Axial Venting Rear Vent with No Vertical Rise The horizon...

Page 14: ...mended to prevent condensation on window 12 30 D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet 60 cm from the center line of the terminal 18...

Page 15: ...n connecting the 551DVK terminal directly to the appliance Max 24 before elbow Min 12 rise 45 elbow directly on flue collar is allowed with min 6 pipe between elbows 1 min all around vertical pipe 3 m...

Page 16: ...ows or equivalent 2 x 45 degrees 90 degrees can be used 5 Each 90 degrees elbow installed on the horizontal plane is equivalent to a 3 feet horizontal pipe therefore 3 feet must be subtracted from all...

Page 17: ...ance with the dimensions shown in the Co Axial Venting section of this manual Drop a plumb from the ceiling to the center of the appliance vent opening Mark the position on the ceiling Drill a small h...

Page 18: ...solid fuel burning fireplace and chimney The appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance Requires 556CLA Co Axial to Co Linear Appliance Adapter...

Page 19: ...and seal inside the rear outlet opening Secure the inner collar with 8 screws 5 Fit the outer collar over inner collar Loosely fit the 12 screws Place the adapter 817VAK or Valor terminal kit 551DVK o...

Page 20: ...Bend the 12 inch stand off and fix it to the appliance case with the two screws just removed as indicated 5 Place the appliance in position in the framing 6 Secure the appliance to the studs Note The...

Page 21: ...each type of installation To fit the restrictors loosen the two center screws of the left and right inlet ports Place the restrictor assembly under the screw heads and tighten the center screws To set...

Page 22: ...the gas supply connection to the appliance Pressure test the supply line for leaks The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pre...

Page 23: ...as forward as possible against the left edge of the firebox 3 Hold the right hand side panel at an angle and insert its bottom edge inside the firebox Rotate the panel to a vertical position ensuring...

Page 24: ...ther end in the crook of the front right log 5 Identify the middle cross log It does not have a hole underneath Place its narrow end on the flat depression in the rear log next to the right cross log...

Page 25: ...ing them through 90 degrees 3 Hook the window baffle to the top of the window frame Be careful not to hook it onto the firebox frame see images below 4 Grab the top of the window and baffle and pull t...

Page 26: ...Do not force it or damage the pins on the receiver box 4 Take the switch wire and plug it into the receiver s connection slot as indicated the other slot should already be fitted with the valve s wir...

Page 27: ...ocks and window installed Increasing aeration will cause the flames to appear more transparent and blue showing more ceramic rock glow Decreasing aeration will cause the flames to appear more yellow o...

Page 28: ...te film If the film is left for a longer period of time it will bake on It is then much harder if not impossible to remove NEVER use an abrasive cleaner on the ceramic glass Any abrasion of the surfac...

Page 29: ...the window frame Be careful not to hook it onto the firebox frame see image below and page 25 4 Grab the top of the window and baffle and pull them forward and release to check that the window opens...

Page 30: ...r and pull it out from its location 2 Slide and remove the receiver cover 3 Replace the 4 AA batteries 4 Replace the cover 5 Put the receiver back in its position pushing it in so it attaches to the V...

Page 31: ...tor turns automatically to maximum flame height 1 Make sure that the MAN knob on the valve is in ON position 2 Make sure that the switch on the valve is in the I position 3 Press and hold the OFF and...

Page 32: ...pressing either the or buttons Mode Sun Moon TEMP Daytime temperature setting Nighttime temperature setting TIMER Start time setting Stop time setting Flame Height The flame height can be adjusted in...

Page 33: ...efore you get up P1 start time and to turn off when you leave for the day P1 stop time Then you can set your fireplace to turn on again at the end of the day P2 start time and to turn off when you go...

Page 34: ...here natural gas was not available at the time of initial installation 650PGK Propane Gas Conversion Kit For conversion from natural gas to propane gas Hearth Gate optional Hearth gates such as Kidco...

Page 35: ...uding near the floor If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMATIC IGNITION MAN knob 2 in ON position Ensure Flame...

Page 36: ...36 36 Wiring Diagram Wall Switch Kit Connector Red Yellow GV60 Wiring Diagram...

Page 37: ...36 Vent Adapters Couplers Universal Adapter 3 Flex Coupler 2150 TM CFAA3 Co linear Flex Connector 46DVA ADF Co axial to Co linear Adapter 46DVA GCL TM 4CAA 556CLA Co linear to Co axial Adapter 46DVA G...

Page 38: ...B SV4B Flat Roof Flashing 46DVA FF TF 4F SV4F 559FSK Masonry Flashing TF 4MF Various Venting System Parts Wall Thimble 46DVA WT 4DT WT TM 4WT SV4RSM Storm Collar 46DVA SC 4DT SC TM SC SV4AC Decorative...

Page 39: ...on for air from other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards i This warranty does not...

Page 40: ...Burner plate 4001966 33 Gaskets module plate sides 2 3000399 34 Gaskets module plate front back 3000400 35 Valve mounting bracket 4000141 36 Thermocurrent interruptor 4001037 Key Description Part no 3...

Page 41: ...41 41 60 41a NG LPG 15 17 22 23 24 25 26 18 19 20 21 16 36 35 4 4a 34 3 3 9 14 2 8 13 50 55 56 57 58 59 51 52 53 54 1 5 6 7 28 27 33 32 29 30 31 43 49 48 46 45 44 38 37 40 41 47 42 39 12a 12b 11a 11b...

Page 42: ...natural gas LPG propane Serial No Front Trim code description e g 660LSV Landscape Surround Purchase date mm dd yyyy Home Owner Name Address City Province State Postal Code Zip Phone Email Address Sto...