Valor 530XAN/XAP Installation Instructions Manual Download Page 35

35

35

Code

Description

Part no.

Code

Description

Part no.

1

Side wall support (2)

330A898

36

Elbow injector NG/LPG

720A580 / 9730013

2

Rear wall support

320B320

37

Inlet pipe

030A224

3

Battery shield

330A908

37a

Inlet pipe adapter

220K997

4

Velcro strip

4000022

37b

Valve to inlet pipe 
connector

220K891

5

Brick retainer

4000828AH

38

Pilot pipe

030A226

6

Inner vent collar

340B174

39

Snap off olive nut

220K913

7

Inner vent collar seal

620B973

40

Window support

320B399

8

Top vent collar seal

568399

41

Valve unit assy incl. 
42/43/44

4000251

9

Top vent cover plate

330A902

42

Valve to main burner pipe 
connector

220K891

10

Wall bracket spacer (2)

320B360AZ

43

Valve cover

4000801

11

Outer vent collar seal

568399

44

Pilot ignition wire 

700K736

12

Outer vent collar

330A888

44A

Servo motor

4000802

13

Restrictor plate #6 (coals)

320B463

45

Remote receiver

4000328

14

Restrictor plate #5 (coals)

320B458

46

Hand held control

4000327

15

Restrictor plate #4 (coals)

320B457

47

Wall mount plate

9000008

16

Restrictor plate #1 (logs)

320B396

48

Wiring harness

4000329

17

Restrictor plate #2 (logs)

320B397

49

Ceramic coal set

000B245

18

Restrictor plate #3 (logs)

320B405

50

Centre left coal

640K615

19

Window unit

050A216

51

Base coal

650K237

20

Spring loaded bolt (2)

000B214

52

Centre right coal

640K616

21

Burner unit incl. #22 
NG/LPG

3000025 / 740K185

53

Front right coal

640K618

22

Aeration shutter assy NG

4000682 / 3000220

54

Front left coal

640K617

22

Aeration shutter LPG

568559

55

Ceramic log set

4000162

23

Pilot unit complete NG/
LPG

4000062 / 4000063

56

Right middle log

4000372

24

Pilot injector NG/LPG

720A575 / 720A195

57

Right side front log

4000470

25

Thermocouple

4000061

58

Front log

4000370

26

Hooked olive for pilot

720A196

59

Base log

4000368

27

Electrode

720A543

60

Left middle side log 

4000371

28

Electrode nut

720A200

61

Rear log

4000369

29

Olive nut for pilot

420K385

62

Ceramic reversible walls 
set

4001160

30

Pilot shield

4000144

31

Pilot support bracket

330A904

32

Main burner pipe

030A225

33

Olive nut

220K567

34

Olive

420K342

35

Base support bracket (2)

330A894

Replacement Parts

Summary of Contents for 530XAN/XAP

Page 1: ...Operating Instructions Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Installation and service must be performed by a qualified inst...

Page 2: ...hould you encounter an operational problem call your dealer immediately Do not try to repair the unit as you may cause an injury or damage the fireplace The information contained in this installation...

Page 3: ...onfigurations 13 Vertical Termination Installations 15 Appliance Preparation 17 Air Restrictors Installation 20 Remote Control Installation 21 Gas Supply Installation 22 Aeration Setting Check 23 Cera...

Page 4: ...llation manual NO OTHER vent system or components MAY BE USED This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a separate sol...

Page 5: ...uipment is installed in a crawl space or an attic the hard wired carbon monoxide detector with alarm and battery back up may be installed on the next adjacent floor level b In the event that the requi...

Page 6: ...side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases but identifies special venting systems the following requirements shall be satisfied by the man...

Page 7: ...30X engine is available in either natural gas or propane gas and comes equipped with either a simulated log or coal fuel bed in either fuel A pebble set is also offered as an optional feature See Opti...

Page 8: ...pressure must be between the limits shown in the Ratings table on the previous page The supply connection is 3 8 NPT female The opening for the gas supply line is at the rear left corner of the applia...

Page 9: ...o prevent condensation on window 12 30 D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet 60 cm from the center line of the terminal 18 46 E Cl...

Page 10: ...ard may be required if terminating within 7 0 of grade or where accessible In Corner No Vertical Rise Maximum 1 x 45 elbow allowed Maximum 18 horizontal pipe length Terminal guard may be required if t...

Page 11: ...es 32 33 for allowable components 14 36 cm max combustible wall 530 engine Top Outlet w Vertical Rise Horizontal Termination See Conversion to Top Outlet for Solid Direct Vent Co axial Piping in Appli...

Page 12: ...rough the outer tube and the appliance collar with 6 screws Make sure the drill does not penetrate the inner pipe Secure the vent unit or 817VAK to the outer collar with two 6 thread cutting screws su...

Page 13: ...depending on the particular installation 1 5 16 33 mm min clearance to combustible materials all round 40 12 2 m max Total offset 4 6 137 cm max Ceiling firestop Roof flashing Approved vertical termi...

Page 14: ...ey systems no combustible construction The appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance Flashing 2 x 3 liners 24 1 2 3 min bend radius Co linear ad...

Page 15: ...ce the appliance in its proper location Drop a plumb from the ceiling to the center of the appliance vent opening Mark the position on the ceiling Drill a small hole at the marked position Determine t...

Page 16: ...s on to the appliance Drop the 3 dia flexible liners into the chimney from outside Fit the liners to the co linear adapter paying attention to inlet and exhaust and move the appliance to its proper po...

Page 17: ...end of the burner Push in the lighting knob and turn counter clockwise through the IGN position to PILOT A spark should flash across from the pilot electrode to the pilot burner shield Window Removal...

Page 18: ...r vent collar and seal by unscrewing 8 screws To make sure that the collars are axially aligned fit the adapter 817VAK over the outer vent collar Position the inner collar and seal vertically inside t...

Page 19: ...ter to the outer collar with two 6 thread cutting screws supplied 1 2 3 1 2 3 4 5 Co linear Conversion using Valor 556CLA Co linear Adapter Note Instructions may vary as 556CLA may be installed on Top...

Page 20: ...e restrictors remove the center screws from the rear ports and fit the restrictors using these screws To set the restrictors at maximum port opening slacken the bottom screws in the ports slide the re...

Page 21: ...wires are pointing up and slot in the board is in line with the tab on the wiring harness plug Connect wires as shown below Please note that the L connectors are different sizes the smaller one fits...

Page 22: ...s The supply line should include a manual shut off valve and union to allow the appliance to be disconnected for servicing Pressure test the supply line for leaks The appliance and its individual shut...

Page 23: ...n in this manual for adjustment details The shutter setting is very critical A change of 1 64 can make a substantial difference to the performance Ceramic Walls Installation The 530 engine is provided...

Page 24: ...log Locate the left side log on the ceramic pin on the left hand side of the base log Rest the narrow nose of this log on the projection at the front center of the base log ensure that the narrow nose...

Page 25: ...the right front coal behind the metal lip at the front of the firebox Its left side should rest over the projection on the left front coal The center right coal has letter R embossed underneath Place...

Page 26: ...liance and the remote control See the Lighting Instructions on page 30 of this manual for full details Aeration adjustment As described on page 23 the burner aeration is adjustable For the vast majori...

Page 27: ...d damage See page 17 To refit the window place it centrally against the firebox while resting it on the support at the bottom of the firebox Pull the clamping bars forward and rotate inwards to secure...

Page 28: ...ts the minutes Set the time Note You must start setting the time while the F is flashing If it stops flashing go back to 1 The display shows C 24 hour or F 12 hour To change the temperature hour displ...

Page 29: ...P1 appears and flashes Let go While flashing push the buttons hour and minutes to set the time at which you want your fireplace to turn on in the morning Press the TIMER button and hold it until P1 a...

Page 30: ...2 Set the flame adjustment knob as far clockwise as possible 3 Turn the gas control knob clockwise to OFF NOTE The knob cannot be turned from PILOT to OFF unless it is pushed in partially Do not force...

Page 31: ...rofitted at a later date Bedroom Remote Kit 562BRK Automatic shut off remote control kit for bedroom installation Circulating Fan Kit 555CFK Having variable speed and temperature control it is designe...

Page 32: ...Snorkel 14 Rise 982 4DT ST14 Snorkel 36 Rise 981 4DT ST36 Vent Adapters Couplers Universal Adapter 3 Flex Coupler 2150 Co linear Flex Connector 923F Co axial to Co linear Adapter 923GCL 556CLA Co line...

Page 33: ...hing 0 12 6 12 943 4DT AF6 SV4FA Roof Flashing 7 12 12 12 943S 4DT AF12 SV4B Flat Roof Flashing 943F SV4F Various Venting System Parts Wall Thimble 942 4DT WT SV4RSM Storm Collar 953 4DT SC SV4AC Deco...

Page 34: ...other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards This warranty does not cover glass log br...

Page 35: ...ate 4 coals 320B457 47 Wall mount plate 9000008 16 Restrictor plate 1 logs 320B396 48 Wiring harness 4000329 17 Restrictor plate 2 logs 320B397 49 Ceramic coal set 000B245 18 Restrictor plate 3 logs 3...

Page 36: ...3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 33 32 34 35 36 37 37a 37b 38 39 40 41 42 43 44 44a 45 46 47 48 NG LPG 50 51 52 53 54 55 56 57 58 59 60 61 62 49 Replacem...

Reviews: