18
18
Conversion to Top Outlet for Solid Direct Vent
Co-axial Piping
If installing with rear vent outlet, go to next step.
Remove the top plate and seal by unscrewing 12
screws. Keep the seal, plate and screws for
fi
tting to
the back.
Remove the rear outer vent collar and seal by
unscrewing 12 screws.
Remove the rear inner vent collar and seal by
unscrewing 8 screws.
To make sure that the collars are axially aligned,
fi
t the
adapter #817VAK over the outer vent collar.
Position the inner collar and seal vertically inside the
top of the appliance. Drop the outer collar with adapter
over the inner collar to ensure alignment. Secure the
inner collar with 8 screws and the outer collar with 12
screws.
Fit the plate and seal (which was previously removed
from the top) to the back of the appliance with 12
screws.
1.
2.
3.
4.
5.
6.
Appliance Preparation