14
3.
6
CONVERTING THE GAS
Caution : The following procedures must be undertaken by authorized service
personnel.
You appliance can be adjusted to operate with LPG or Natural Gas. The burners can be
altered to work with different types of gas by switching their injectors and adjusting the
minimum flame length suitable to the gas in use. To change the injectors, these steps must
be followed:
Changing injectors:
Hob Burners:
-
Turn off the gas and electric supply that's going to the appliance.
-
Remove the hob cap and the adaptor.
-
Unscrew the injectors using a 7mm spanner.
-
Replace the injectors with the ones from the spare set, and use the information chart
that's provided with the spare set to fit the injectors on with the correct diameters suited to
the gas fuel that is going to be used.
C
hanging the Oven/Grill injectors:
T
he oven and grill injectors are assembled by a single screw that is on the tip of
the burner.
For grill burners, this screw is already visible. Remove the screw and pull the grill burner
towards you and you will see the injector revealed on the rear surface of the oven cavity.
For oven burners, open the drawer compartment and you will see the assembly screw below
the burner. Remove the screw, move the burner diagonally and the injector will be revealed on
the rear side of the burner box.
Remove the injectors with a 7mm spanner and replace the injector with the ones from the
spare set, with corresponding diameters suitable to the type of gas that is going to be used,
according to the information chart (which is also supplied in the spare set).
Screw