10-1/2”
(267 mm)
7-1/2”
(191 mm)
7-1/8”
(181 mm)
3”
(76 mm)
Flashing
2 x 3”
liners
3” min.
bend radius
Co-linear
adapter
2 x 3”
liners
Co-linear
adapter
Linear
engine
Approved co-linear
termination or approved
co-linear adapter
and approved
co-axial
termination
Dura-Vent #46DVA-GCL Co-Axial
to Co-Linear Adapter
Co-Linear installation into existing F/P
Roof
Pitch
Minimum
"H" (feet)
Flat to 7/12
1'
Over 7/12 to
8/12
1.5'
Over 8/12 to
9/12
2’
Over 9/12 to
10/12
2.5’
Over 10/12 to
11/12
3.25’
Over 11/12 to
12/12
4’
Over 12/12 to
14/12
5’
Overhang should not
extend beyond vent if
within 48” of
termination cap
Horizontal
overhang
Vertical
wall
Min. 24”
(unvented soffit)
Min. 36”
(vented soffit)
Termination
cap
Min.
18”
Storm
collar
Roof
flashing
‘H’
Vertical Vent Termination
Co-axial Venting
Conversion to Co-Linear Liners using generic Co-Linear Adapters
Co-linear portion of vent system may only be installed within a solid-fuel burning fi replace and chimney.
The appliance must not be connected to a chimney
fl
ue serving a separate solid-fuel burning appliance.
Requires a Co-Axial to Co-Linear appliance Adapter, two lengths of 2-ply 3” dia.
fl
exible chimney liner approved for
venting gas appliances, a co-linear termination kit and
fl
ashing or a co-linear to co-axial adapter and either a high
wind vertical vent terminal cap or a low pro
fi
le vertical
termination.
Firebox zero clearance standoffs supplied
with the heater are not required for this application
.
Rules for Co-Linear Venting
• Maximum 40 feet vertical pipe
• Minimum 10 feet vertical
• Maximum offset 8 feet with liners at minimum 45
degrees from horizontal plane
• Restrictor: Use #4 position for all co-linear
installations—refer to page 30 for restrictor positioning.
Co-Linear Venting
Any fi nishes
applied
around the
fi replace
must be non-
combustible
QUALIFIED
INSTALLER