![Valor 1200EAN (NG) Installation And Owner'S Manual Download Page 28](http://html1.mh-extra.com/html/valor/1200ean-ng/1200ean-ng_installation-and-owners-manual_3300466028.webp)
28
Co-axial Venting
HORIZONTAL
TERMINATION
2-PIECE
WALL
THIMBLE
PIPE
LENGTH
PIPE
LENGTH
PIPE
LENGTH
PIPE
LENGTH
90˚ ELBOW
CEILING
FIRESTOP
ATTIC
FIRESTOP
ATTIC
INSULATION
SHIELD
FLASHING
STORM
COLLAR
VERTICAL
TERMINATION
Important Installer Notice – Weather Sealing &
Vapor Barriers
It is the installer’s responsibility to ensure that vent installations
through exterior walls are caulked and weatherproofed in such a
manner as to:
• Prevent rain water from entering the wall from the weather side
by adequately caulking the outer vent plate to the exterior wall
surface.
• Prevent moisture inside the home from penetrating into the wall
structure by ensuring the inside wall plate is adequately sealed to
the inside vapor barrier.
• Prevent rain water and moisture from entering the walls by
sealing the joints between the outer vent tube and the inner and
outer wall plates.
We recommend the use of a high quality polyurethane sealant.
Typical Venting Components
QUALIFIED
INSTALLER