Valor 1000KN Installation Manual Download Page 20

20

39-1/2” [1004 mm]

32-1/4” [819 mm]

1035BPB-RC 3-Sided Plate

40” [1016 mm]

33-1/4” [845 mm]

from bottom of plate

1040BPB-RC 4-Sided Plate

32-3/8” [822 mm]

from bottom of appliance

7/8” [22 mm]

Backing plate overhangs 

bottom of appliance

3ODWHȵXVKZLWK

bottom of appliance

39-1/2” [1004 mm]

36” [914 mm]

1036BPB-RC 3-Sided Plate

3ODWHȵXVKZLWK

bottom of appliance

23-7/16” [596 mm]

31-1/8” [791 mm]

6-5/8” dia. venting

ȴHOGFRQYHUWLEOH
IURPWRSWRUHDU
RXWOHW

&HQWHURIYHQW

ȋFOHDUDQFH
IURPYHQWSLSH

ȋIURPEDFN
RIEDFNLQJSODWH

Backing Plates and Fronts—Reduced Clearance

Retrofit Application

Overview

Summary of Contents for 1000KN

Page 1: ...ow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier...

Page 2: ...s reserved Designed and manufactured for Miles Industries Ltd Valor Fireplaces 190 2255 Dollarton Highway North Vancouver BC Canada V7H 3B1 T 604 984 3496 F 604 984 0246 valorfireplaces com This appli...

Page 3: ...axial Adapter 31 Appliance Preparation 32 Convert Vent Outlet if required 32 Install Stand offs 33 Remove Convection Baffle 34 Install HeatShift Take Off Collars 34 Remove Window 35 Installation 36 In...

Page 4: ...n is installed Solid wood flooring in front of the fireplace if al lowed may shrink during the heating season due to heat Some materials or items although safe may discolor shrink warp crack peel and...

Page 5: ...the outside and must never be attached to a chimney serving a separate solid fuel burning ap pliance Each gas appliance must use a separate vent system Common vent systems are prohibited Intended use...

Page 6: ...mum Supply Pressure in w c 10 14 Main Burner Injector Marking 750 260 Pilot Injector Marking 51 30 Min Rate By Pass Screw 175 105 Supply Gas Heater engines 1000KN is used with natural gas Heater engin...

Page 7: ...C 4 Sided Backing Plate Black Reduced Clearance 4007347AZ with 1041FSV 4 Sided Surround Vintage Iron with 1041FSCB 4 Sided Surround Champagne Brass Information accurate at the time of printing and sub...

Page 8: ...ter of vent 1 1 2 38 mm m 3 5 16 85 mm 9 1 2 242 mm 15 381 mm 28 7 16 722 mm 17 3 8 441 mm 34 1 16 865 mm 35 13 16 909 mm 23 1 4 590 mm 27 7 8 709 mm Optional HeatShift ports 4 x 4 HUR OHDUDQFH WR 6WD...

Page 9: ...Mantel Projection from Face of Cement Board Mantel Height from Bottom of Unit Ceiling 65 Min to Ceiling 49 42 39 35 32 26 5 8 with HeatShift ONLY Note Use of the optional HeatShift System a ects mant...

Page 10: ...10 34 1 16 Fireplace Opening Wall Min 5 to wall Face of Finished Wall FIREPLACE Note Right Side Clearances are the same Combustible Sidewall Mantel Leg Top View Mantel Clearances...

Page 11: ...sh thickness including header is approx 5 maintaining 1 clearance to vent Flush to bottom of appliance 1036BPB RC 3 Sided tall backing plate 1045CFV Clearview Front NO Flush to bottom of appliance 104...

Page 12: ...eather protected environments as defined in the GV60CKO Outdoor Conversion Kit instruction manual Overview WARNING SAFETY WARNING The H3 is a very effective radiant heater HOT WALL SURFACES The wall d...

Page 13: ...1 4 7 mm Backing plate overhangs bottom of appliance 3ODWH XVK ZLWK bottom of appliance 30 13 16 783 mm from bottom of plate 40 1016 mm 1030CIK Clean Installation Kit 37 9 16 954 mm 34 863 mm 1 5 8 4...

Page 14: ...ition 1 4 below bottom of appliance 36 15 NOTE This unit requires a solid platform to support it Combustible framing DOORZHG EHQHDWK UHSODFH 39 Between underside of header and base of heater DVH RI KH...

Page 15: ...combustibles around vertical vent pipe Approx 5 127 mm from back surface of ZDOO QLVK WR IURQW surface of appliance FDVH Z QR YHQW R VHW 9 1 2 242 mm PARTIAL SHELF top outlet 1 2 PP WKLFN non combusti...

Page 16: ...siderations Dimensions of venting are based on us ing Dura Vent elbows Elbow curve radius dimensions will vary when using other brands In general other brands have slightly bigger radius 3 inches clea...

Page 17: ...fireplace when installed in a new construction application requires a 13 mm thick non combus tible cement board or equivalent to be used as a wall surface immediately above the unit see diagram for mi...

Page 18: ...eed 200 F Below are some tips on how to best avoid any cracking Allow materials to dry thoroughly before finishing the wall Cement board has the ability to absorb up to 30 percent of its weight in wat...

Page 19: ...lower combustible header height of 33 and combustible wall finishes from 31 of the base of the H3 appliance The outer dimensions of the RC backing plates are larger to cover a larger range of existing...

Page 20: ...plate overhangs bottom of appliance 3ODWH XVK ZLWK bottom of appliance 39 1 2 1004 mm 36 914 mm 1036BPB RC 3 Sided Plate 3ODWH XVK ZLWK bottom of appliance 23 7 16 596 mm 31 1 8 791 mm 6 5 8 dia vent...

Page 21: ...stible wall assembly up to 8 inches in thickness A non combustible wall can be of any thickness up to the maximum horizontal run of vent pipe allowed for the particular installation Tape all joints in...

Page 22: ...L TERMINATION 2 PIECE WALL THIMBLE PIPE LENGTH PIPE LENGTH PIPE LENGTH PIPE LENGTH 2 2 CEILING FIRESTOP ATTIC FIRESTOP ATTIC INSULATION SHIELD FLASHING STORM COLLAR VERTICAL TERMINATION Venting Typica...

Page 23: ...acted from allowable horizontal run 45 degrees elbow is equivalent to 18 inches horizontal pipe 7 All horizontal pipe runs must be graded 1 4 inch per foot upwards in the direction of the exhaust flow...

Page 24: ...6 5 8 top outlet HOG FRQYHUWLEOH WR UHDU RXWOHW Max 18 pipe length ZLWK QR YHUWLFDO ULVH use of 45 HOERZ RN 1 min DOO DURXQG YHUWLFDO SLSH 3 min DERYH WRS RI KRUL RQWDO SLSH PLQ DURXQG ERWWRP VLGHV R...

Page 25: ...ction required depends on the vertical rise in the venting system and to a lesser degree the horizontal run and number of elbows The amount of restriction is based on laboratory tests The ideal restri...

Page 26: ...n 15 feet 4 6bm below the terminal 36 90 I Clearance to service regulator vent outlet 36 90 J Clearance to non mechanical air supply inlet to the building or the combustion air inlet to any other appl...

Page 27: ...24 unvented soffit Min 36 vented soffit Termination cap Min 18 Storm collar Roof flashing H Vertical Vent Termination Venting Co axial Roof Pitch Minimum H feet Flat to 7 12 1 Over 7 12 to 8 12 1 5 O...

Page 28: ...ear appliance adapter two lengths of 2 ply 3 diameter flexible chimney liners approved for venting gas appliances a co linear termination kit and flashing or a co linear to co axial adapter and either...

Page 29: ...m 10 feet vertical Maximum o set 8 feet with liners at minimum 45 degrees from horizontal plane Restrictors are not required when using co linear vent ing Note Co linear liners must only be installed...

Page 30: ...m o set 8 feet with liners at minimum 45 degrees from horizontal plane Note Flexible co axial liners must only be installed within a solid fuel burning fireplace and chimney Flex Co Axial installation...

Page 31: ...Terminal Configurations 10 10 3 Inlet Exhaust Collars 7 5 8 dia collar Flashing Kit Co Linear Terminal typical Co axial Terminal Cap Co Linear to Co Axial Adapter Flashing With Alternate Co linear to...

Page 32: ...ify that you have all the components re quired for the installation including approved non combustible cement board if required liners and fuel bed in separate cartons backing plate and trim kit with...

Page 33: ...rofitting in existing framing Leave the stand o s flat on appliance case 2 For new construction framing swivel up flat stand o s bend them as shown and secure loose end to top of firebox Appliance Pre...

Page 34: ...ction Ba e Remove the convection ba e from the appliance It is held in place by 3 screws located right behind the upper edge of the fireplace opening Recycle this panel as it is no longer needed Top o...

Page 35: ...box 1 To remove the window locate the levers on each side of the window towards the top Using your fin ger pull the lever towards you and unhook it from the window frame bracket 2 Gently pull the top...

Page 36: ...other at risk individuals Hearth considerations You need to know whether there will be a hearth or not in front of the appliance and some rules must be considered Without hearth up the wall In the cas...

Page 37: ...H PDWHULDO LQVXODWLQJ Micore SDQHO PLQ ZLGH GHHS VXSSOLHG VHSDUDWHO PD WKLFNQHVV LQFOXGLQJ Micore Lower panel Removable panel 1 5 8 42 mm Front of appliance Plywood base Appliance base Lower panel Ply...

Page 38: ...Align the appliance with the cavity and push it in until the front face is flush with the studs 3 Install the lower panel using the three bolts at the base of the appliance 3 nuts 4 On the appliance...

Page 39: ...g points per side Use wood screws not supplied with this kit Installation 1030CIK Clean Installation Kit 8 Set aside the side doors removable panel and barrier screen to install later when the appli a...

Page 40: ...ombustible flooring Install Appliance for 3 or 4 Sided Trims and Fronts new construction only 3 sided trims 1035 and 4 sided trims 1040 are fitted to appliance once its installation and wall finish ap...

Page 41: ...eneral Requirements The optional 1095CFK kit includes a three prong grounded plug to plug into a grounded receptacle also included with the kit to be installed within the fireplace enclosure by a qual...

Page 42: ...m de mand of the appliance without undue loss of pressure Sealant used must be resistant to the action of all gas constituents including LP gas Sealant should be applied lightly to male threads to ens...

Page 43: ...ation or servicing All leaks must be corrected immediately When testing for leaks Make sure that the appliance is turned o Open the manual shut o valve Test for leaks by applying a liquid detergent or...

Page 44: ...anel anchor down to hold the panel in place 4 Insert the bottom of the other side liner panel between the burner and the side wall and rotate it slightly to insert it totally inside the firebox Push i...

Page 45: ...irch Log Kit 1000BLK Material required Birch Log Kit which contains 13 logs 1 x 0 180 lb bag of embers Gloves if desired Installation Carefully unpack the kit Note each log has its own number stamped...

Page 46: ...d of the groove in front of H4 Note the angled feature of H11 should be pointed to the right side 10 Place log H10 into the left end of the groove Angled end 11 Place some embers into the groove betwe...

Page 47: ...in H1 17 Place log H3 as shown Note the hole in H3 fits onto the pin in H1 18 Place log H7 on top of H6 as shown 19 Place remaining embers as desired You may not need to use all the embers 20 The comp...

Page 48: ...urner platform or other logs Install the logs as shown below 1 Place the shale embers into the recess in front of the burner Be careful not to overfill and block any burner ports You may have more emb...

Page 49: ...7 on the right hand pin on top of H15 and balance the other end on the burner support plate 6 Place log H16 on the left hand pin on top of H15 and balance the other end on the burner support plate 7 P...

Page 50: ...top of H4 under H16 11 Place the pebbles anywhere you like within the ar rangement H15 H20 H18 H4 H19 H5 H21 H17 H16 12 The completed arrangement will look like the one below Note some minor adjustmen...

Page 51: ...or other logs Install the logs as shown below 1 Place log H11 into the right hand side of the cavity in front of the burner 2 Place log H10 into the left hand side of the cavity in front of the burne...

Page 52: ...s 6 Place log H12 on top of the embers between H10 and H11 7 Place log H25 on the support plate behind the burner Note there is a tab at each end that fits into a cutout at each end of the log 8 Place...

Page 53: ...in place 12 Place log H29 into the groove on top of H4 and H30 Installation 13 Place log H28 behind H26 and top of H29 14 The completed arrangement will look like the one below Note some minor adjustm...

Page 54: ...fireplace damage components cause overheating resulting in dangerous conditions Damage caused by incorrect window installation is not covered by the Valor Warranty Hot Glass Warning Plate Bottom raili...

Page 55: ...sure the ignition wire DOES NOT TOUCH the receiver s antenna IMPORTANT The connection can only be done one way Do not force it or damage the pins on the receiver box 7 Insert 4 AA alkaline batteries i...

Page 56: ...and hold the receiver s reset button until you hear one short and one long beeps Release the reset button after the second beep 4 Within the subsequent 20 seconds press the small flame button on the r...

Page 57: ...aeration The need for adjustment should be determined only by operating the appliance with the fuel bed panels and window installed and evaluating the flame picture after a 15 minute warm up Increasin...

Page 58: ...s holder is not required in all installations but is provided as an optional feature for those customers who wish to mount the remote handset to the wall To install the holder to the wall find a conve...

Page 59: ...r RESET Button PANEL red yellow Receiver red Interruptor Block Thermal Safety Switch IGNITOR Connector Optional 1265WSK Wall Switch Kit Combination Control Valve Antenna Main Valve Knob MAN Knob PILOT...

Page 60: ...TM 4CAA 4DCAB33 1000CLA 940106433 Co linear to co axial Adapter 46DVA GK 46DVA CLTA 4DT CTB TM 4CTA 4DCAT33 Co axial to ex co axial Adapter 1000CAA DV to B Vent Adapter DVA5BV Adjustable Pipe Length...

Page 61: ...Flashing 7 12 12 12 46DVA F12 4DT AF12 TF 4FB SV4B 4DF12 6 12 12 12 949606712 Flat Roof Flashing 46DVA FF TF 4F SV4F 949606001 Masonry Flashing TF 4MF 559FSK New Siding Flashing 658NSFK Various Venti...

Page 62: ...xt adjacent floor level b In the event that the requirements of this subdivision can not be met at the time of completion of installation the owner shall have a period of thirty 30 days to comply with...

Page 63: ...side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases but identifies special venting systems the following requirements shall be satisfied by the man...

Page 64: ...IRU JDV LQFOXGLQJ QHDU WKH RRU I RX VPHOO JDV 6723 ROORZ LQ WKH VDIHW LQIRUPDWLRQ DERYH RQ WKLV ODEHO I RX GRQ W VPHOO JDV JR WR WKH QH W VWHS 8720 7 1 7 21 0 1 NQRE LQ 21 SRVLWLRQ QVXUH ODPH GMXVWPHQ...

Page 65: ...ettings OFF returns to set mode turns the burner and WKH SLORW R DUJH DPH EXWWRQ DPHV up sets hours temperature 6PDOO DPH EXWWRQ DPHV GRZQ DQG R VHWV PLQXWHV temperature Current temperature F or C Cur...

Page 66: ...red and compared to set temperature Flame height automatically adjust to reach Daytime Set Temperature Light Dimmer Mode Not available on this replace Fan Mode Turns fan ON and OFF and adjusts speed N...

Page 67: ...tton until TEMP ashes To set Night Time Temperature increases temperature decreases temperature Press or wait to complete setting Setting Program Timers You can program two periods of time between 12...

Page 68: ...matically extinguishes the pilot This feature helps the consumer realize cost bene ts by automatically eliminating energy consumption during non heating months and limited use The programmed length of...

Page 69: ...adually increase flame height Press and hold small flame button to gradually decrease flame height The Wall Switch can be used to control your fireplace You can turn the pilot on or o and you can incr...

Page 70: ...ening for locating televisions artwork etc Approvals The LDK8 kit is CSA approved for use only with Valor Series replaces listed above DO NOT use with any other models This HeatShift system may also b...

Page 71: ...se with the H3 replace if HeatShift is to be implemented The LDK10 and LDK11 are optional accessories but some approved liner and clamps are required See Approvals on the previous page for size and ra...

Page 72: ...also be o set to accommodate WARNING The plenum duct kits are approved for horizontal discharge ONLY DO NOT install plenum in oor or ceiling DO NOT COVER OR PLACE objects in front of or on top of air...

Page 73: ...rigid 4 UL 181 Class 1 Air Duct 4 Use LDK11 kit or equivalent Ceiling 28 7 16 722 mm Min 42 1067 mm Min 2 1 2 clearance to ceiling 39 991 mm Top of plenum opening must be minimum 7 and maximum 12 off...

Page 74: ...ing Min 1 clearance to combustibles around pipes Support horizontal sections of pipe using strapping every 24 DO NOT RUN pipe horizontal Minimum slope 4 12 Min bend radius 4 4 4 12 Vertical Rise Y Min...

Page 75: ...mbustibles around pipes and to sides and rear of plenum No combustible in this area No combustible in this area Top of stand offs See installation manual for minimum non combustible cavity dimensions...

Page 76: ...the upper edge of the replace opening Recycle this panel as it is no longer needed Top of replace shown transparently for clarity Install HeatShift Take O Collars 1 Remove the two cover plates on top...

Page 77: ...s collars clear framing Min 1 clearance to combustibles rear and sides Side View 6 Paint the inside surfaces of the plenum using high temperature at black spray paint for installations where the insid...

Page 78: ...Glass 4007205 Description Part Number 1 Duravent intake collar 4000925 2 Intake collar gasket 4000942 3 Intake plate 4007050 4 Intake plate gasket 4007056 5 Top stand o s 2 4007051 6 HeatShift cover p...

Page 79: ...irch Log Set 1000BLK Log no H1 4007463 Log no H2 4007464 Log no H3 4007465 Log no H4 4007466 Log no H5 2 4007467 Log no H6 4007468 Log no H7 4007469 Log no H8 4007470 Log no H9 4007471 Log no H10 4007...

Page 80: ...80 Appendix E Spare Parts 47 46 48 21 25 26 27 14 28 28a 19 20 17 18 16 33 35 36 34 37 38 39 40 42 41 15 29 31 32 30 1 2 3 4 5 5 13 9 10 11 12 7 7 8 44 43 45 51 52 53 54 63 49 50 55 56 59 57 58 6 6 6a...

Page 81: ...81 Appendix E Spare Parts 60 61 62 H1 H2 H3 H7 H11 H12 H10 H8 H6 H9 H5 H5 H4 1000BLK H15 H16 H17 H18 H20 H5 H21 H19 16 12 9 9 H4 1000DWK 1000LSK...

Reviews: