![Valor 1000KN Installation Manual Download Page 14](http://html1.mh-extra.com/html/valor/1000kn/1000kn_installation-manual_3282191014.webp)
14
26-5/8” between underside
of non-combustible board
and base of heater.
1/2” thick non-combustible
board required above engine
(not supplied). See page
A hearth is not required. However, if installing
a hearth, consider the following:
VLGHGEDFNLQJSODWHVDUHȵXVKZLWKKHDUWK
4-sided backing plate position 1/4” below
bottom of appliance.
36”
15”
NOTE: This unit requires
a solid platform to support
it. Combustible framing
DOORZHGEHQHDWKȴUHSODFH
39”
Between underside of header and base of heater.
%DVHRIKHDWHUPXVWEHDWȴQLVKHGKHDUWKKHLJKW
However,
please note that the 1040BPB 4-sided
backing plate extend 1/4” below the base of heater
.
Increase cavity height accordingly.
16.
Framing & Hearth
New Construction
Combustible hearth or fl ooring is
allowed if fl ush with or below the base
of the appliance.