12.2. Measurement
Measurement menu shows the Valmet MCA measure-
ment results.
MCA: MCA-1234
Measurement
1 Sensor Type
FT200
2 Cs
0.00 %Cs
3 Prc Temp
57.3 °C
4 Status
OK
5 Conductivity
2.43 mS/cm
6 % of range
36.72 %
7 mA
9.88 mA
8 meas Att
32.4 dB
Recipe # OFF
Sensor Type:
Cs:
Measured consistency.
Prc Temp:
Process temperature.
Status:
Device status (OK, Alarm, etc.).
Conductivity:
Process conductivity.
% of range:
Consistency current output value as a
percentage of the current output range.
mA:
value of ... in milliampers.
meas Att:
The measured microwave damping in the
process.
Recipe #:
The number of the recipe in use (refer to
Chapter 9.3).
12.3. Configure
In Configure menu you can configure Valmet MCA's
current output and certain other parameters. Configure
menu also shows device information.
M C A :
M C A - 1 2 3 4
C o n f i g u r e
1
R a n g e
V a l u e s
2
U s e r
s e t t i n g s
3
D e v i c e
i n f o
4
S E N S O R
E L E C T R O N I C S
5
T C U
6
S e t
C l o c k
Range values
LowRnge:
Consistency that correlates to current output
lower limit 4 mA.
UppRnge:
Consistency that correlates to current out-
put upper limit 20 mA.
Damping:
Damping time of the current output.
Alarm cur:
How the output signal reacts to error situ-
ations detected by self-diagnostics. Options: 3.7 mA /
22.5 mA / freeze.
User settings
Trend Int:
The sampling interval of the devices´s in-
ternal trend table.
Pos:
Device position information.
Lang:
TCU language version.
Temp unit:
Process temperature unit °C / °F.
Installation & Owner’s manual OUL00298 V2.3 EN
52
Valmet Mircowave Consistency Transmitter
Summary of Contents for Valmet MCA
Page 2: ......
Page 4: ...Installation Owner s manual OUL00298 V2 3 EN 4 Valmet Mircowave Consistency Transmitter...
Page 8: ...Notes Installation Owner s manual OUL00298 V2 3 EN 8 Valmet Mircowave Consistency Transmitter...
Page 24: ...Notes Installation Owner s manual OUL00298 V2 3 EN 24 Valmet Mircowave Consistency Transmitter...
Page 32: ...Notes Installation Owner s manual OUL00298 V2 3 EN 32 Valmet Mircowave Consistency Transmitter...
Page 34: ...Notes Installation Owner s manual OUL00298 V2 3 EN 34 Valmet Mircowave Consistency Transmitter...
Page 44: ...Notes Installation Owner s manual OUL00298 V2 3 EN 44 Valmet Mircowave Consistency Transmitter...
Page 58: ...Notes Installation Owner s manual OUL00298 V2 3 EN 58 Valmet Mircowave Consistency Transmitter...
Page 60: ......