background image

3

© Vallox Oy - All rights reserved

MANU

AL

1

2

4

min. 500 mm /  

 

650 mm

3

Electrical connection

CAUTION

The minimum distance of the 

bottom edge of the grease 

filter to an electric cooker is 

500 mm, and to a gas cooker 

650 mm.

CAUTION

•  The cooker hood must 

not be connected to a flue 

that is used for removing 

combustion gases (e.g. 

from a wood- or gas-

burning fireplace, cooker, 

or stove).

•  The cooker hood must 

not be fastened through 

the side panels to the 

cabinets.

•  Fans that are controlled 

through the cooker hood 

must have an engine 

cover and their maximum 

power must not exceed 

340 W.

•  Regulations on leading 

extraction air outdoors 

must be observed.

POWER PLUG

G23 LED

INSTALLATION

Use the mounting accessories included in the package 

to fasten the cooker hood in place.

1.   Shorten the extract air duct to be connected to the 

hood (125 mm spiral duct) to the correct length.

2.  Where required, install a Vallox cover strip, for 

instance, (2142400 cover strip 500 or 2142500 

cover strip 600) to cover the opening in the rear 

wall.

3.  Lift the hood so that it is in contact with the duct.
4.  Fasten the cooker hood with the mounting 

brackets or by other means, so that the hood is 

firmly in place and cannot move (figures 1, 2 and 

3). The mounting screws included in the accessory 

bag are suited to walls made of wood, chipboard, 

cement or stone. Use appropriate mounting 

devices for other materials.

5.  Check the tightness of the extract air duct system.
6.  Plug the cooker hood into the mains. Ensure that 

the plug can be unplugged, where required.