background image

Vallox Pureo

Control

Quick guide

Model

Vallox Pureo Control panel

Document

D10799

 

Valid from

25.06.2021

Updated

20.10.2021

Control panel

MANU

AL

Summary of Contents for Pureo

Page 1: ...Vallox Pureo Control Quick guide Model Vallox Pureo Control panel Document D10799 Valid from 25 06 2021 Updated 20 10 2021 Control panel MANUAL...

Page 2: ...instructions 4 Compatibility of the Vallox Pureo control panel 4 Control panel buttons 5 Control panel symbols 6 USING THE UNIT 7 Ventilation speed limits 7 Fan speeds 8 Speed control 8 Pressure contr...

Page 3: ...ructions concerning transportation installation use or maintenance Structural or electronic modifications or changes made to the software INTENDED USE All Vallox air handling units have been designed...

Page 4: ...N THE INSTRUCTIONS WARNING Indicates a hazard that can result in death or serious injury if not avoided IMPORTANT Indicates a hazard that can result in damage to property or loss of data if not avoide...

Page 5: ...atus of the unit The Back button takes you backwards in the menu The Left arrow button takes you leftward in the menu The Right arrow button takes you rightward in the menu Press the OK button to conf...

Page 6: ...ning status is fast The week clock is in use On off status information of the unusual running status of the unit Alarm class 1 An alarm that stops the unit has been activated Alarm class 2 An alarm th...

Page 7: ...k clock icon is not shown on the main display at other times Slow Fast Week clock If the running status of the unit deviates from the setting shown on the control panel the on off status information i...

Page 8: ...ntrol or air volume control and the running status to either slow or fast as required by the control method or setting the maximum boost speed NOTE The fan settings menu shows and enables editing the...

Page 9: ...9 Vallox Oy All rights reserved Vallox Pureo Control USING THE UNIT Pressure control Air volume control IMPORTANT Pressure control requires external duct pressure sensors...

Page 10: ...oling frost prevention and efficiency limit settings and to start a test run Fan settings The Fan settings menu is used to select speed control pressure control or air volume control as the control me...

Page 11: ...urn When the unit requests a confirmation select OK To view the results of the test run press the Down arrow NOTE The air handling unit must be turned on when the test run is activated The test run do...

Page 12: ...UI8 The outdoor air sensor located inside the duct has become damaged Extract air sensor UI4 The extract air sensor has become damaged Exhaust air sensor UI5 The exhaust air sensor has become damaged...

Page 13: ...te and time are set from the Time settings menu Week clock The week clock allows you to pre set a weekly ventilation programme for the air handling unit You can set one of the following speeds for eve...

Page 14: ...ature inside the duct Supply air temperature after the HR cell Return water temperature of the heating radiator Efficiency of the HR cell Supply air fan rpm Extract air fan rpm External boost voltage...

Page 15: ...the unit off To turn off the air handling unit select Turn off and confirm the selection by pressing OK If the unit has been turned off from the control panel the air handling unit can be turned on b...

Page 16: ...D10799 20 10 2021 www vallox com Vallox Oy Myllykyl ntie 9 11 32200 LOIMAA FINLAND Vallox Oy All rights reserved...