background image

5

© Vallox Oy - All rights reserved

 

INTRODUCTION

VENTILATION UNIT CONTROL 

Ventilation unit control options.

Operation of the Vallox ventilation unit can be controlled by the 

following means:

•  Through the My Vallox Control panel installed in the building.

•  Through the MyVallox Home local area network connection 

and the MyVallox Home/Cloud user interface.

•   Through the MyVallox Cloud service and the MyVallox Home/

Cloud user interface.

•   Through a remote monitoring service or building automation 

that uses voltage signals or Modbus messages.

In addition to the integrated humidity and carbon dioxide sensor, 

ventilation can also be adjusted automatically by using the 

optional carbon dioxide, humidity, or VOC (air quality) sensor. 

When these are used, ventilation remains optimal even when 

the dwelling is unoccupied. Each user can use the week clock to 

adjust the ventilation to fit their individual lifestyle. 

Connecting the ventilation unit to the cloud 

service

The ventilation unit can be connected to the MyVallox Cloud 

service. The cloud service allows for controlling ventilation 

remotely also, using e.g. a smartphone or tablet. Also the unit 

software is updated automatically through the cloud service. 

To connect to the cloud service, the ventilation unit must be 

connected to the Internet via LAN and registered with the cloud 

service. At the same time you create a MyVallox Cloud account 

for yourself. Read more about the service at www.myvallox.com.

IMPORTANT

Apartment-specific 

ventilation units allows 

residents to adjust the 

ventilation efficiency. 

Ventilation is controlled 

based on the need e.g. 

through the cooker 

hood, ventilation 

control panel, or a 

separate control centre. 

In order to ensure that 

the indoor air presents 

no harm to health and 

remains optimal also 

for the structures of the 

building, 

ventilation 

must be kept on 

without disruptions. 

It is recommended 

that ventilation be 

left turned on during 

long holidays also. 

This keeps the 

indoor air fresh and 

prevents humidity 

from condensing in 

the ventilation ducts 

and structures. It also 

reduces the risk of 

moisture damage. 

NOTE

For the MyVallox Cloud/

Home instructions, 

please go to www.

techmanuals.info/

ValloxMV/ENG/

onlinehelp/webhelp

IMPORTANT

Prolonged overpressure 

can result in damage 

to the structures of the 

building.

Summary of Contents for C3741

Page 1: ...Manual Model Vallox 101 MV Type C3741 Document D5331 Valid from 05 05 2021 Updated 03 05 2021 Ventilation unit MANUAL...

Page 2: ...required by the alternative Vallox Silent Klick siphon installation method elbow 9 Measuring and adjusting the air flows of the ventilation unit 9 Dimensions and duct outlets 10 MAINTENANCE 11 Before...

Page 3: ...al installations and connections must be carried out only by an electrician and in compliance with local regulations GUARANTEE The guarantee and liability exclude damage resulting from Inappropriate u...

Page 4: ...result in death or serious injury if not avoided IMPORTANT Indicates a hazard that can result in damage to property or loss of data if not avoided CAUTION Indicates a hazard that can result in minor...

Page 5: ...ws for controlling ventilation remotely also using e g a smartphone or tablet Also the unit software is updated automatically through the cloud service To connect to the cloud service the ventilation...

Page 6: ...figure MAIN PARTS Post heatingresistor in the supply air duct 8 Safety switch 9 Internal carbon dioxide and humidity sensor 10 Control panel 11 Carbon dioxide sensor optional 12 Humidity sensor option...

Page 7: ...p edge of the white covering strip of the ceiling mounting plate can be installed against the ceiling Alternatively a concealed mounting method can be used in which case the ceiling can be 30 mm below...

Page 8: ...x can be accessed The distance between the service door and the ceiling mounting plate must be around 500 mm Alternatively the cables can be fed between the ceiling mounting plate and the ventilation...

Page 9: ...ing tubes These can be inserted in the ducts to allow for easier ventilation adjustment NOTE The Vallox Silent Klick siphon package is delivered with the unit Installation instructions for the siphon...

Page 10: ...ating resistor in the supply air duct 9 Safety switch 10 Internal humidity and carbon dioxide sensor Dimensions and duct outlets Dimensions Duct outlets R model Inner diameter of the female collar 125...

Page 11: ...very cell clean The filter replacement interval depends on the ambient particle concentration It is recommended that the filters be replaced every spring and autumn or at the very least once a year To...

Page 12: ...rip E in place so that the strip is supported by the corner bracket G at the rear 13 Install the extract air filter C in place 14 Close the door Ensure that the safety switch catch of the door is touc...

Page 13: ...the fans J 3 screws per fan Undo the mounting screws K 3 screws of the air flow control grille of the extract air fan and remove the grille 8 Remove the fan from the unit by pulling it forward and by...

Page 14: ...m s 15 24 34 42 51 62 69 77 83 23 31 41 50 60 70 78 86 92 Air flow m h 54 86 122 151 184 223 248 277 299 83 112 148 180 216 252 281 310 331 Medium frequency of the octave band Hz 63 62 64 69 73 77 82...

Page 15: ...elay output T Supply air fan P Extract air fan M Damper motor TK Safety switch AHS Post heating control RH Internal humidity sensor RH CO2 Internal humidity and carbon dioxide sensor R1 Post heating r...

Page 16: ...2x0 5 0 5 2x0 5 2x0 5 CAT Analog input two different functions Potential free contact data 24VDC can be programmed to display information such as errors or to control the valve and pump of the MLV rad...

Page 17: ...rd MLV control External temperature sensor NTC 4K7 MB_A External Modbus A signal MB_B External Modbus B signal 24V 24V voltage DC GND Digital and analog ground potential RS_A Local hardware Modbus A s...

Page 18: ...ature setting In winter the duct radiator will turn on when the outdoor temperature falls below the winter setting Manual In summer the duct radiator will turn on when the outdoor temperature rises ab...

Page 19: ...ve Not included in the delivery The valve that is chosen must be compatible with the heat collection circuit fluid for example ELV05006 Stig Wahlstr m K Condensing water tube Not included in the deliv...

Page 20: ...24 MyVallox Control panel 949033 5 Coarse and fine filter for supply air 978225 15 Mounting screw of the door 990712 25 MyVallox humidity sensor optional 946149 6 HR cell aluminium HR cell enthalpy 93...

Page 21: ...CONFORMITY CERTIFICATES...

Page 22: ...22...

Page 23: ...23 Vallox Oy All rights reserved...

Page 24: ...D5331 03 05 2021FIN 03 05 2021ENG PDF www vallox com Vallox Oy Myllykyl ntie 9 11 32200 LOIMAA FINLAND...

Reviews: