CONTROL METHODS

In winter use

  the heat recovery cell of VALLOX 75 and VALLOX 95 recovers heat from the

air leaving the dwelling and uses it to heat the air coming from the outside.

Electric radiator

VALLOX 75 / 95 units feature a 500 W post-heating radiator.The temperature of supply
air is adjusted at the thermostat regulatorlocated inside the unit.Adjustments can be made
within the range of 0...25

°

C.

POST-HEATING

In summer use

 the heat recovery cell is bypassed in VALLOX 75 and VALLOX 95 with anin-

built damper.

In the summer position airflow through the cell is prevented, and heat recovery bypass is
activated.

REMOTE MONITORING CENTRE VALLOX 1993 A

• ON/OFF switch
• Operating status data to remote monitoring
• Transformer with eight voltage options,

of which two + one preselected

• Can be controlled with a timer or through

remote monitoring, for example.

Depth:

100 mm

Height:

180 mm

Width:

255 mm

SEPARATE CONTROL CENTRE 1992A 0.85 A

Depth: 90 

mm

Height: 140 

mm

Width: 110 

mm

• 4-step adjustment
• ON/OFF switch

SEPARATE CONTROL CENTRE 1992A EK 0,85 A

Depth:

90 mm

Height:

140 mm

Width:

110 mm

• Separate 4-step adjustment switch
• ON/OFF switch

COOKER HOOD X-LINE PTX/PTXP(A) 500/600 0,85 A

Depth:

500 mm

Height:

140 mm

Width:

498/598 mm

• Washable grease filter, easy to remove
• Bright, long lasting fluorescent lamp
• Outlet collar with rubber ring

HEAT RECOVERY BYPASS

Summary of Contents for 75

Page 1: ...Handy ceiling mounting plate for simple and quick mounting Service switch as standard All models are available as R and L models Fans 105 W 65 dm3 s 90 Pa 105 W 75 dm3 s 130 Pa 180 W 85 dm3 s 75 Pa 1...

Page 2: ...1 VALLOX 75 95 DIMENSIONS PERFORMANCE 2 2 Pressure loss in ducts Total pressure SFP Specific Fan Power guideline value 2 5 kw m3 s SFP Input power total W Air flow max dm3 s Dimensions and duct outlet...

Page 3: ...19 31 34 40 43 47 19 25 33 38 43 62 68 75 78 86 82 86 37 43 51 54 60 60 64 41 56 65 65 71 72 76 41 48 55 57 63 67 69 30 34 42 45 50 54 58 24 28 34 36 40 43 46 15 24 34 37 40 42 44 17 27 30 35 38 43 1...

Page 4: ...prevented and heat recovery bypass is activated REMOTE MONITORING CENTRE VALLOX 1993 A ON OFF switch Operating status data to remote monitoring Transformer with eight voltage options of which two one...

Page 5: ...unit starts automatically as soon as the risk of freezing has passed The threshold temperature of the risk of freezing can be set at the thermostat J of the water radiator Though VALLOX 75 95 VKL unit...

Page 6: ...front edge of the collar When detaching the damper take the same steps in the opposite order Self actuated one way dampers are only used in VKL model units B C Detaching of thermostat sensor from and...

Page 7: ...iator The overheat protector T2 of the radiator R is triggered and power supply to the heating unit is stopped if the temperature of the thermostat exceeds 80 C The overheat protector is reset manuall...

Page 8: ...ture of water radiator goes below the threshold value preventing the risk of freezing in the water radiator This also causes self actuated one way dampers SP to close preventing the flow of outdoor ai...

Page 9: ...230 V 160 V 120 V 70 V L N 90 V 135 V 180 V 1 5 X 1 5 S 2 3 PL 11 L 1 2 3 230 V 160 V 120 V 70 V L L 2 N 90 V 135 V 4 L2 180 V 1 2 3 PL 11 0 4 N L3 N VALLOX 75 95 3510 external electrical connection w...

Page 10: ...Wire colours m black r brown s blue T2 F1 F2 K TK m s s s s s m m m m m L N N 1 L T1 m m K r r N L m 1 m s L 1 s V W 2 3 3 X 1 5 S L 10 A N N 1 L N L 1 L L N L 3 2 N INTERNAL ELECTRICAL CONNECTION OF...

Page 11: ...NITORING VALLOX 75 95 control through remote monitoring with control centre 1993 YK 2A VALLOX 1993A YK 2A VALLOX 75 95 REMOTE MONITORING CONTROL CENTRE DISTRIBUTION PANEL OPERATING STATUS DATA OPERATI...

Page 12: ...e approximately 40 kg The ceiling mounting plate has to be fixed horizontally in order to ensure that the unit will be straight Installation Lift the unit straight upwards till the locking wings on th...

Page 13: ...s wall mounting accessories with the exception of screws The unit has to be mounted horizontally and vertically straight Wall construction Pay attention to the wall construction when mounting the unit...

Page 14: ...nted The delivery does not include a water seal nor the pipe and its components Examples of condensing water connections Yli 600 n 100 n 100 Suction air COLLECTOR condensing water goes to the cellar W...

Reviews: