7
© Vallox Oy - All rights reserved
MV
NOTE
For the MyVallox Cloud/
Home instructions,
please go to www.
techmanuals.info/
ValloxMV/ENG/
onlinehelp/webhelp
Connecting the ventilation unit to the cloud
service
The ventilation unit can be connected to the MyVallox Cloud
service. The cloud service allows for controlling ventilation
remotely also, using e.g. a smartphone or tablet. Also the unit
software is updated automatically through the cloud service.
To connect to the cloud service, the ventilation unit must be
connected to the Internet via LAN and registered with the cloud
service. At the same time you create a MyVallox Cloud account
for yourself. Read more about the service at www.myvallox.com.
Brightness of the light
To adjust the brightness of the light:
1.
Turn on the light, close the damper, and set the ventilation
to the Away mode.
2. Press the selection button for roughly 3 seconds until the
setting mode signal light starts to flash.
3. Adjust the brightness of the light by pressing the light
button until the brightness is adequate.
4. To save the setting, press the selection button for roughly 3
seconds until the setting mode signal light stops to flash.
To read about the other functions of the selection button, go to
our website, www.vallox.com.
Guard function
The cooker hood has a guard function that is activated when
the temperature of the cooker hood e60 °C or after
a sudden increase in temperature (> 8 °C/min). In such a case,
all signal lights of the cooker hood and the LED light will flash,
the fans of the ventilation unit will stop, and the damper of the
cooker hood will close. If this kind of alarm is noticed before fire
damage, it can be acknowledged by pressing any of the cooker
hood buttons.
INTRODUCTION
Summary of Contents for 51 MV
Page 33: ...CONFORMITY CERTIFICATES ...
Page 34: ...34 MV ...