14
MV
CAUTION
The minimum clearance
between the bottom
edge of the cooker
hood and an electric
stove is 426 mm.
INSTALLATION OF THE VALLOX
CAPTURA COOKER HOOD
The Vallox Captura cooker hood is installed on the bottom of
Vallox 51K MV.
1. Remove the plug from the feedthrough seal of the
condensing water tube of the cooker hood (Figure 1).
2. Lift the cooker hood and fit the hooks at the rear of the
cooker hood into the holes at the bottom of the ventilation
unit. Push in place (Figure 2).
3. Ensure that the feedthrough seal of the condensing water
tube sits firmly around the tube.
4. Lift the front of the cooker hood to fit the mountings into the
penetrations in the bottom of the ventilation unit (Figure 3).
5. Fasten the M5 hexagon screws (2) through the mountings
(Figure 4).
Lead the power cord and the control cable up along the
cable channel (Figure 3). Wind approx. half a metre of the
cables behind the cooker hood so that it can be removed for
maintenance purposes where required. Move the metal cover
backwards so that it covers the opening between the cooker
hood and the wall (Figure 5).
1
2
3
4
5
INS
T
ALLA
TION
Summary of Contents for 51 MV
Page 33: ...CONFORMITY CERTIFICATES ...
Page 34: ...34 MV ...