10
TECHNIC
AL SPECIFIC
ATIONS
Air flow
measurement
points
Measurement points after
the outlet collar. The fan
curves indicate the total
pressure accounted for by
duct losses.
TECHNICAL SPECIFICATIONS
Product title
Vallox TSK Multi 80 MC R
Vallox TSK Multi 80 MC L
Product number
3478000
3478100
Air volumes Supply air
Extract air
85 dm3/s, 100 Pa
91 dm3/s, 100 Pa
Electrical connection
230 V, 50 Hz, 8.8 A power plug
Enclosure protection class
IP 34
Post-heating
Electric resistor, 900 W
Preheating
–
Additional heating
Electric resistor, 900 W
Fans
Supply air
Extract air
0.081 kW 0.65 A EC
0.081 kW 0.65 A EC
Specifi c energy consumption (SEC)
in a cold climate
in a temperate climate
A+
B
Operating effi ciencies*
Annual effi ciency
Supply air effi ciency
Specifi c Fan Power (SFP)
79 %
86 %
1.26 kW/m3/h (60 dm3/s)
Filters
Supply air
Extract air
ISO Coarse > 75 % + ISO ePM₁
ISO Coarse > 75 %
Heat recovery bypass
Automatic
Dimensions (w x h x d) and weight
1026 x 293 x 626 | 58.5 kg
*Working point defi ned in the Ecodesign Directive (2009/125/EC), Southern
Finland, Helsinki-Vantaa TRY year 2012.
VALLOX TSK MULTI 80 MC
Supply air
View from above
2
1
2
4
3
1
3
4
Le
ft s
id
e
Rig
ht
s
id
e
Extract air
Combined input power of the fans (kW)
Airflow specified in the ventilation plan (m3/s)
SFP =
SFP rate (Specific Fan Power)
recommended value <1,8 kW (m3/s)
ED and SD are examples of pressure loss
in the supply and extract air ducts.
S = supply air
E = extract air
Supply/extract air volumes
Volume flow rate (dm3/s)
Fan input power
Volume flow rate (dm3/s)
Power (W)
SFP 1,5
SFP 1,8
SFP 1,0
0
36
72
108
144
180
216
252
m³/h
(l/s)
dm³/s
0
50
100
150
200
250
300
350
0
10
20
30
40
50
60
70
80
90
100
11,4 V
8,3 V
7,2 V
6,3 V
5,2 V
4,1 V
3,2 V
288
324
360
0
25
50
75
100
125
150
175
200
0
10
20
30
40
50
60
70
80
90
100
dm³/s
(l/s)
m³/h
36
72
108
0
144
180
216
252
288
324
360
11,4 V
7,2 V
6,3 V
4,1 V
3,2 V
8,3 V
5,2 V
Pressure loss in ducts. Total pressure (Pa)