8
TECHNIC
AL SPECIFIC
ATIONS
600
545
583
38
L model
Inner diameter of the female collar: 125mm
1. Exhaust air out
2. Outdoor air to the unit
3. Supply air to the apartment
4. Extract air from the apartment to the unit
R model
Inner diameter of the female collar: ø125mm
1. Supply air to the apartment
2. Extract air from the apartment to the unit
3. Exhaust air out
4. Outdoor air to the unit
93
102
298
363
600
141
459
407
430
1
4
2
3
Air flow measurement points
Measurement points after the outlet collar. The fan curves
indicate the total pressure accounted for by duct losses.
Supply air
Extract air
TECHNICAL SPECIFICATIONS
Nimike
Vallox 096 MC R
Vallox 096 MC L
Product number
3474600
3474700
Air volumes Supply air
Extract air
92 dm3/s, 100 Pa
95 dm3/s, 100 Pa
Electrical connection
230 V, 50 Hz, 5.1 A power plug
Enclosure protection class
IP 34
Post-heating
Electrical resistor, 900 W
Pre-heating
–
Additional heating
–
Fans
Supply air
Extract air
0,119 kW 0,9 A EC
0,119 kW 0,9 A EC
Specifi c energy consumption (SEC)
in a cold climate
in a temperate climate
A+
B
Operating effi ciencies
Annual effi ciency
Supply air effi ciency
Specifi c Fan Power (SFP)
75% A+
85.7%
1.0 kW (38 dm3/s) B
Filters
Supply air
Extract air
ISO Coarse > 75 % + ISO ePM₁
ISO Coarse > 75 %
Heat recovery bypass
Automatic
Dimensions
(w x h x d) and weight
600 x 545 x 428 | 53 kg
DIMENSIONS AND DUCT
OUTLETS
Duct outlets
Dimensions