15
© Vallox Oy - All rights reserved
INS
TALLA
TION
CONDENSING WATER CONNECTIONS
Installation of the Vallox Silent
Klick siphon on the bottom pool
Installation of the Vallox
Silent Klick siphon on the
wall. The elbow underneath
the unit takes less space
than the siphon.
47
38
75
55
Elbow
Installation height: 38 mm, installation space: 47 mm
Installation height: 55 mm, installation space: 75 mm
Vallox Silent Klick siphon
600
R model
L model
121
143
143
121
Location of the condensing water outlets, R and
L models
If the Vallox Silent Klick siphon does not fit into the unit
directly, the elbow can be installed at the bottom, and
the siphon can be installed on the wall. This installation
method requires that there is a 47mm space underneath
the unit. The elbow requires a 38mm space when
installed.
5
395
8
15
15
630
5
395
8
15
15
630
5
395
8
15
15
630
Attic floor penetration plate (optional)
When an attic floor penetration plate is used, the tightness of the vapour barrier has to be ensured.
The minimum
distance from the rear
wall is 5 mm
The minimum
distance from the
side walls is 15 mm
Installation of the Vallox Silent Klick
siphon on the wall
Installation of the Vallox Silent Klick
siphon on the bottom pool
The delivery includes the Vallox Silent Klick siphon.
A pipe will be connected to the siphon that leads the
water that is condensed from the extract air to the floor
drain (not directly into the sewer). The pipe must not rise
after the siphon. The ventilation unit must be installed
straight to ensure that condensing water can exit the unit
unobstructed.