![Valley Classic Owner'S Manual Download Page 21](http://html2.mh-extra.com/html/valley/classic/classic_owners-manual_3235522021.webp)
Valley Classic Control Panel
21
Overview
Start-Stop / Safety Override Switch
The control panel is equipped with a combination
Start-Stop Safety Override rocker switch. See Figure
21-1.
To start the machine, press and hold the switch in
the START position for approximately three seconds
and then released at which time the switch will return
to the center neutral RUN position. See Figure 21-1.
If the machine safety circuit is complete, the safety
return light will remain lit and the machine will con-
tinue to run. See Figure 21-1.
To stop the machine, move the rocker switch to the
STOP position. See Figure 21-1.
If the machine safety circuit is broken (open) due to
span misalignment, it will be necessary to override
the safety circuit momentarily to realign the machine.
However, the machine must be in full view of the op-
erator, if the machine is not in full view of the opera-
tor, DO NOT override the safety circuit.
When the Start-Stop switch is held in the START
position, the machine safety circuit is bypassed and
the machine will run until the switch is released. The
switch should never be held in the START position
for more than three seconds at any one time.
To override the machine safety circuit, press and
hold the switch in the START position for no more
than three seconds at any one time. See Figure 21-1.
Inspect the entire machine after each safety override
attempt.
!
WARNING
• REPEATED SAFETY OVERRIDE ATTEMPTS
CAN CAUSE SEVERE STRUCTURAL DAM-
AGE. CALL YOUR LOCAL VALLEY DEALER
SHOULD THE MACHINE FAIL TO START.
Safety Return Light
The small light above the Start-Stop rocker switch is
the Safety Return Light. See Figure 21-1.
When lit, it indicates that there is power going out
to the end of the machine and coming back to the
control panel on the safety circuit.
This indicator lamp will also light when the Start-Stop
rocker switch is pressed to the start position.
CAUTION
DANGER
High Voltage!
480 Volts can kill.
Lock Machine Power
in the “OFF” position
before opening cover.
0997326
Do not operate system when temperature
is below 40° F (4.5° C)
Read and understand the valley operator
manual before operating this equipment.
CAUTION
0997300
CAUTION
DO NOT HOLD BUTTON DEPRESSED
LONGER THAN 3 SECONDS. REPEATED
START ATTEMPTS CAN CAUSE SERIOUS
STRUCTURAL DAMAGE
0997302
OFF
ON
TEST
Classic
1
2
Figure 21-1 1. Start - Stop - Safety Override Switch
2. Safety Return Light