12. Initialization for counting sample objects: Every time use the pieces counting function, the 

user  must  initialize  different  number  of  objects  for  the  scale.  First,  press  down  the  “PCS” 
button to switch the scale to the counting mode from the weighing mode, and the screen 
will  display  “0”  at  the  time.  Then,  press  down  “PCS”  button  again  to  enter  the  sample 
collecting  process,  and  the  screen  will  display  “PC-25”  now,  which  means  the  sample 
collected  objects  should  be  25  pieces.  In  the  meantime,  press  down  the  “PCS”  button 
different  time can change the sample collected  objects  to 50 pieces or 100 pieces,  whose 
sign  in  the  screen  will  be  “PC-50”or  “PC-100”.  After  assuring  the  number  of  the  sample 
collected objects, putting the exact number of the sample objects on the weighing platform. 
Press down the “PCS” button again and wait for the screen display the number of the objects. 
Remove the sample objects 

13. From  the  platform  and  the  initialization  for  counting  sample  objects  procedure  is  ended. 

Now  the  user  can  put  the  different  number  of  similar  weigh  objects  on  the  platform  for 
starting the counting.

CALIBRATION INSTRUCTIONS

This  scale  had  been  calibrated  before  it  was  dispatched  from  the  factory.  But  at  times  when 
there  is  a  remarkable  change  in  temperature  or  humidity  (including  change  of  seasons),  there 
might be inaccuracies. In this case, please test the scale in the following way: place a standard 
weight on the platform, and if the positive or negative difference exceeds the difference allowed 
as specified in the technical specifications of the weight, please recalibrate the scale according to 
as follows.

Recalibration Function: press down the “MODE” button until the screen displays “000000”.Then, 
remove  your  finger  from  the  button  and  the  display  will  change  to  “E-00”.  Now,  press  the 
“MODE”  button  again  can  recalibrate  the  scale.  The  initial  recalibrated  weigh  is  25kg,and  the 
screen will display “E1-25”,”E2-50”,”E3-100” while each time pressing down the “MODE” button, 
whose  represent  the  recalibrated  weighs  are  25kg,50kg  and  100kg  .Choose  the  required 
recalibrated  weigh  like  50kg  (the  screen  is  displaying”E2-50”  now),  and  the  put  the  50kg 
counterpoises  on the weighing  platform. Wait until the screen displays “GOOD”, and then the 
scale turns off automatically. The recalibration is ended now.

TECHNICAL SPECIFICATIONS

Model

Weighing Mode

Max.capacity & readability

in Different Units

Precision Mode

150kg/ 0.05kg

5290oz/ 1oz

330lb/ 0.1lb

008858623

High Capacity Mode

300kg/ 0.1kg

10582oz/ 3oz

660lb/ 0.2lb

Summary of Contents for 660LB

Page 1: ...Instruction Manual 660LB DIGITAL SCALE Model 008858623 HOUSEHOLD USE ONLY Toll Free 1 888 380 7953...

Page 2: ...es not included Before operating please make sure that batteries have been inserted into the scale Caution 1 Do not use excessive force in either removing or replacing the battery cover 2 If the scale...

Page 3: ...s the TARE button and the display will register 0 00 again You can now place your pet in the carrier or cage to get an accurate weight 8 Another option is to place the empty carrier or cage on the sca...

Page 4: ...librated before it was dispatched from the factory But at times when there is a remarkable change in temperature or humidity including change of seasons there might be inaccuracies In this case please...

Page 5: ...ster an accurate reading E no display Replace or readjust the batteries INSTALLATION DRAWING BILL OF MATERIAL Designation Quantity Explain scale 1 adapter 1 power line 1 specification 1 battery 4 adju...

Page 6: ...Manuel d Instructions 660LB BALANCE DE CUISINE NUMERIQUE Mod le 008858623 A USAGE DOMESTIQUE UNIQUEMENT T l phone Gratuit 1 888 380 7953...

Page 7: ...t de utiliser assurez vous que les batteries ont t ins r es dans la balance Attention 1 Ne pas forcez lors du retrait ou du remplacement du couvercle de la batterie 2 Si la balance ne doit pas tre uti...

Page 8: ...t qu elle n enregistre pas 0 00 appuyez sur le bouton TARE pour la restaurer galement 0 00 7 Lorsque l affichage indique 0 00 placez le support ou la cage vide sur la balance L cran LCD affichera alor...

Page 9: ...cran affichera alors 0 Ensuite appuyez nouveau sur le bouton PCS pour entrer dans le processus de collecte d chantillons L cran affichera PC 25 pr sent ce qui signifie que les objets chantillonn s do...

Page 10: ...recalibr e initiale est de 25 kg et l cran affichera E1 25 E2 50 E3 100 tout en appuyant chaque fois sur le bouton MODE qui repr sente les pes es recalibr es 25 kg 50 kg et 100 kg Choisissez le poids...

Page 11: ...LLATION NOMENCLATURE D signation Quantit Explique balance 1 adaptateur 1 Ligne lectrique 1 sp cification 1 batterie 4 Vis de r glage 4 pendant 1 Seulement pour mod le de portion Vis 4 Seulement pour m...