Page 3: ...ontrol in the future Please read these instructions carefully and completely for your own safety For more infor mation about how to use the device please refer to the table of contents or to the alphabetical index pearly is here to make your life easier throughout 3 pearly ...

Page 4: ... off 13 Return to the time view 13 Self test and trial measurement 13 Serial number software status 13 7 Measurement period Clear the measurement period 14 Change the measurement period 14 8 Measuring your temperature General information 15 Tips 15 Measuring your temperature 15 Measurement errors 16 Cancel the measurement process 16 Measurement symbol not on 16 Measurement free days 16 9 Inputting...

Page 5: ...lysing your cycle data 22 Bluetooth 22 Setting the time and date 22 Fever 23 Deleting stored data 23 Skipping a measurement 23 Mini USB cable 23 Mono phases 23 After the pill 23 Travel Time zones 23 Shift work 23 Pregnancy indicator 24 Summer and winter time 24 Temperature increases 24 Restarting the application after an interruption 24 Restarting the application after a pregnancy 24 13 Technical ...

Page 6: ...bed thus before being active in any way wake temperature basal body temperature If you have recorded your menstruation data in the past then please input them into the device before taking the first measurement Set and activate the alarm before you start using the application In case of a measurement free day reactivate the alarm for the following day The software uses your base data right from th...

Page 7: ...ility indicator Measurement value Measurement symbol Time of day wake up time date Menstruation indicator Intercourse indicator Function keys Press to open Battery indicator Alarm symbol Sensor USB socket Battery compartment 7 pearly ...

Page 8: ...ress briefly hrs hrs Set time Press briefly switch on Device is off Set date Software and serial number Date Serial number trial measurement Wake up time Time of day Time level 07 30 13 46 24 10 14 0100 5 sec Min 5 sec Min press briefly Trial measurement press briefly fertility level pearly 8 ...

Page 9: ...ound connected Starting data synchronisation Displays next 6 days M no IC no 5 sec press briefly M yes IC yes press simultaneously back to time level press briefly press briefly Prognosis Measurement value Fertility indicator cycle day initialised Data transmission Fertility level 36 63 36 65 14 9 pearly ...

Page 10: ... down for 5 seconds Setting confirmed The display stops blinking and sounds a tone to confirm acceptance of this setting Plus key Use the plus key to move to the next field and make an input e g confirm your period Press the plus key to move to the next field in one step Minus key Use the minus key to move to the previous field e g display past measurement values Press the minus key to move backwa...

Page 11: ...you may not only set the time and day but also the month and year 4 Activate the alarm Switch on the device The time will appear at the bottom left Now press the minus key to display the wake up time Press the minus key again and the wake up signal will start to blink Activate the alarm using the plus key or deactivate it using the minus key Ensure that pearly wakes you up on the first day of usin...

Page 12: ... Ovulation day forecast ovulation 8 Entering M in case of menstruation After measuring you will see M menstruati on blinking if the case may be In case of M yes you have your period press the plus key M is on In case of M no you don t have your period press the minus key M will disappe ar from the display Please input M on three successive days at least If you have M your period without being prom...

Page 13: ...tomatically return to the time view Starting from the time view Hold the plus key down for 5 seconds In the first 5 seconds after turning on the device the display shows the serial number of the device and the software status If no key is pressed a self test is run and all symbols are displayed successively and disappear shortly Press the circle key during the serial number view or during the self...

Page 14: ...ate the alarm before taking your first measurement The measurement period is displayed beside a permanent sym bol The measurement period is calculated based on the factual measurement time from the previous day 3 3 hrs 3 3 As a rule the wake up time and measure ment time will be identical and we recom mend to let pearly wake you Should you wake up within the measurement period e g because you have...

Page 15: ...close your mouth The sensor should stay firmly in place during the measurement process The best results are achieved if you choose the same position every time Measuring your temperature pearly wakes you with a tone Press any button to switch the alarm tone off To start measuring you must press another button The Measurement symbol starts blinking pearly is now ready to measure your temperature No...

Page 16: ...ep excessive alcohol consumption etc please read page 24 Measurement errors See page 28 Errors and corrective action Cancel repeat measurement process To skip a measurement or cancel the measu rement process stop the process by pressing the minus and the plus key simultaneously You will hear a tone The device is now cancel ling the measurement process If you wish to repeat the measurement at a lat...

Page 17: ...played alternatingly with the mea surement value Inputting M after using the application for some time As soon as pearly knows your cycle the device will prompt you for M on the day M is expected The M prompt M blinking begins 2 days before your expected period Once M is over pearly will stop prompt ing you for it The first bleeding after discontinuing the pill is a pill induced withdrawal bleedin...

Page 18: ...tion 2 If you had a few measurement free days e g holidays and you had the period you may wish to input M post hoc If no mea surement values have been entered you may start max 99 days back Start with the least recent day If you already have entered some measurement values you may correct M for the past three days Starting from the clock display Press the circle key once Turn back to the required ...

Page 19: ...g M Release the circle key and press briefly again you see a blinking heart Press the plus key confirm intercourse heart is on Or press the minus key delete intercourse heart disappears Input only for the previous day You may only input intercourse for the cur rent day or the day before it has no bearing on the results 10 INPUTTING INTERCOURSE 19 pearly ...

Page 20: ...l get to know your personal cycle The number of green days will continually and prudently increase If the device receives no information or invalid information for some time the number of yellow days will gradually increase Starting from the time view press the circle key once You will see the measurement value of the day alternating with the current cycle day and your input for M if any The trian...

Page 21: ...e actual fertility status determined on the relevant day In case of doubt only rely on the fertility status displayed for the current day Starting from the actual measurement value Press the minus key once By pressing this key repeatedly you will go back to the previous fertility statuses step by step Hold the minus key down for a fast backward Use the plus key to fast forward to home day after da...

Page 22: ...nking to move forward with the plus or backward with the minus key Finish settings hold the circle key down for another 5 seconds A brief signal will confirm your input 10 Printing your data The stored data may be read out if you wish using A mini USB cable and a PC or tablet Or a Bluetooth Smart Ready device and the corresponding app In App Stores for Android and iOS devices our pearly cycle app ...

Page 23: ...activate the alarm using the new measure ment time pearly will be ready for measuring the next morning The same should be done after you return home Shift work Set and activate the alarm to the new measu rement time pearly will be ready to measure Do likewise at the next change of shift see p 11 and 14 Fever If the measurement value indicates a fever higher than 37 80 C F for fever will be display...

Page 24: ...ncy In the first six weeks after a pregnancy there is no fertility risk We recommend starting to measure from the sixth week after giving birth at the latest The device will display yellow until further notice The restarting cycle will be recognized by slight temperature fluctuations pearly will then resume its fertility indication Restarting the application after an interruption The date year and...

Page 25: ...up to a maximum of 1500 hPa Battery 1 micro AAA 1 5 V battery of good quality leaka ge protected or 1 2V nickel metal hydride cell with a low rated self discharge Please adhere to the recommended disposal method The battery status will be displayed when switching on the device if the battery symbol is blinking you should replace the battery as quickly as possible Tip Make sure you have the new bat...

Page 26: ...radiator Do not store your computer in a hot environ ment e g on a hot dashboard in summer High temperatures can damage the batteries and deform or melt certain plastics Do not keep the device in a cold environ ment While it heats up to normal service temperature condensation may occur and cause damage to the inside of the device Do not drop the computer on the floor or expose it to shocks or impa...

Page 27: ...P22 15 PURPOSE AND DESCRIPTION The pearly cycle computer is a battery powered minicomputer used to measure a woman s daily wake up temperature basal body tempe rature in order to determine and visualize her fertile days The fertile period is calculated based on the body temperature that is measured orally right after waking up with the cycle computer sensor then saved and automatically analysed To...

Page 28: ... For any unexpected occurrences or issues arising from use please contact the product manufacturer In case of a sensor defect contact your country distributor For questions about the cycle please contact your country distributor Find your country distributor at www lady comp de Bluetooth connection not possible Bluetooth must be activated on both devices If the display stays on SEARCH check the de...

Page 29: ... minus key 10 Device dimensions material 25 Inputting intercourse 19 Basics 7 Basic rules for all inputs 6 Not making measurements 23 Deleting stored date 23 Inputting menstruation date M 17 Activating M 18 Inputting M 12 Inputting menstruation data M post hoc optional 12 Correcting M 17 M after using the application for some time 17 Inputting M post hoc 18 M after starting the application 17 Meas...

Page 30: ...ce and assistance 28 Safety 26 Safety distances Electromagnetic compatibility 26 Shift work 23 Fast forward fast backward 10 Pregnancy indicator 24 Summer and winter time 24 Faults 28 Technical specs 25 Temperature rise fever 23 24 Tips for measuring your temperature 15 Setting the time 22 USB cable 23 Maintenance 26 Alarm activating 11 Alarm setting 11 Further information 22 Restarting the applic...

Page 31: ......

Page 32: ...Development production and marketing Germany and worldwide VE Valley Electronics GmbH Breite 2 D 82418 Murnau Tel 49 0 8841 48928 0 Fax 49 0 8841 48928 24 info lady comp de www lady comp de Rev Nr 06 19 ...