![VALERA 554.02 Instructions For Use And Installation Download Page 3](http://html1.mh-extra.com/html/valera/554-02/554-02_instructions-for-use-and-installation_3429884003.webp)
7
INSTALLATION INSTRUCTIONS
Wall holder for hairdryer
Type 036 - 038A - 038B
Type 036
Front housing model.
Type 038A
Vertical housing model.
Type 038B
As the 038A but with no switch.
Installation of wall holder
This wall holder must only be installed by a qualified electrician
in conformity to applicable safety standards.
The wall holder may be installed in one of two ways:
A = for fixed connection lead
B = for mobile connection lead
Attention: before installing the wall holder always switch off
the general switch of your mains electricity.
For each pole a switch with a minimum break distance between
contacts of 3 mm must be fitted up-line of the appliance.
Each time the appliance is opened, the switch must be used to
disconnect the appliance.
The connection wiring must be at least type H05VV-F
2x1,0 mm
2
.
Method A
IMPORTANT: Refer to the figures for the model you have
purchased.
1. Unscrew the screw (1) (fig. 1) and remove the cover from the
wall unit.
2. Break the plastic membrane (3) at the back of the wall unit
(fig. 3A).
3. Route the main power cable from the wall (4) through the
hole left by the plastic membrane (3) (fig. 3A).
4. Fix the back of the wall unit to the wall using the fixing screws
and wall plugs provided (fig. 2).
5. Remove the terminal strip (5). The input power cable (4) and
the output power cable (9) of hairdryer with max input current
of 10A,if not already connected, must be connected to the
terminal strip(5).
In mod. 036 the Neutral output cable(9) must be connected
to terminal strip(5) and the Line output cable (9) to terminal
strip (11).
6. Reposition the terminal strip. Tighten the cable clamp
(6 and 10) with its own screws. (fig. 3A). IMPORTANT: This
appliance is double insulated and has no ground (earth)
connection.
7. Fit the cover back on the wall unit with (1) (fig. 1).
8. Switch the power on at the mains switch. The hair dryer is
now ready to use.
Method B
IMPORTANT: Refer to the figures for the model you have
purchased.
1. Unscrew the screw (1) (fig. 1) and remove the cover from the
wall unit.
2. Break the plastic membrane (7) (fig. 3B).
3. Fix the back of the wall unit to the wall using the fixing screws
and wall plugs provided (fig. 2).
4. Route the input power cable (8) and the output power (9)
into the holes (fig. 3B).
5. Remove the terminal strip (5). The input power cable (8) and
the output power cable (9) of hairdryer with max input current
of 10A,if not already connected, must be connected to the
terminal strip(5).
In mod. 036 the Neutral output cable(9) must be connected
to terminal strip (5) and the Line output cable (9) to terminal
strip (11).
Reposition the terminal strip. Tighten the cable clamp (6 and
10) with its own screws. (fig. 3B). IMPORTANT: This appliance
is double insulated and has no ground (earth) connection.
6. Fit the cover back on the wall unit with (1) (fig. 1).
7. Switch the power on at the mains switch. The hair dryer is
now ready to use.
INSTRUCTIONS FOR USE
Hairdryer with wall holder
Control Switches
Control switch on wall holder
(only for models equipped with a switch) rif. 2 fig. 1:
0-1 = Off/On
Hairdryer
Type 533.03 - 533.05 - 533.03/I - 533.05/I
542.05 - 542.06 - 542.14 - 561.22
Pushbutton:
ON=On/Off
(pressure must be maintained to operate the hairdryer)
• Allow your appliance to cool before storing away and do not wrap the supply
cord around the hairdryer in storage.
• The A-weighted sound pressure level of the hairdryers for commercial use is
below 70 dB(A).
• Designation of the appliance (see technical product specifications)
WALL-MOUNTED HAIRDRYER FOR COMMERCIAL USE
00060721 int_dic2016:Layout 1 13/12/2016 8.36 Pagina 7
Summary of Contents for 554.02
Page 44: ...48 www valera com 30 III 8 n 00060721 int_dic2016 Layout 1 13 12 2016 8 36 Pagina 48...
Page 53: ...57 www valera com 30 mA III 8 00060721 int_dic2016 Layout 1 13 12 2016 8 36 Pagina 57...
Page 62: ...66 I I i i www valera com 30 III 8 i 00060721 int_dic2016 Layout 1 13 12 2016 8 36 Pagina 66...
Page 65: ...69 www valera com 30 III 8 00060721 int_dic2016 Layout 1 13 12 2016 8 36 Pagina 69...
Page 68: ...72 WWW VALERA COM 30 MA III 8 00060721 int_dic2016 Layout 1 13 12 2016 8 36 Pagina 72...
Page 73: ...77 VALERA 1 44 99 CE 24 6 2 3 4 5 6 00060721 int_dic2016 Layout 1 13 12 2016 8 36 Pagina 77...
Page 78: ...00060721 int_dic2016 Layout 1 13 12 2016 8 37 Pagina 82...