Aerosphere World / Midibus
36
3.3
Command Description - Test Operation
3.3.1 Test Mode
This mode is used to diagnose the system checking the inputs and activating
the outputs.
To access this mode, perform the following the steps:
- Press the keys
+
. The display will indicate - -, asking for entering
the access password. The access password is 14.
- Use the key
for increasing the first digit and key
for decreasing the
second digit until the correct password is shown on the display.
- Press
to confirm. In case the typed password is incorrect, the panel
will return to indicate the vehicle internal temperature. After verifying the
password, the panel will indicate
,so that all inputs may be tested.
- Press
for alternating between the inputs and the outputs.
- By pressing
, the panel will indicate
or
, depending whether it is
an input or an output. When it is an input , the ventilation LED speed 2
will show the input status. If it is blinking the input is off, otherwise it is on.
- When you select an output
, press
for turning it on and/or off. The
ventilation LED speed 2 will be on indicating the output is on.
- Press
or
for alternating between other inputs or outputs. When
you alternate the output function, the previous function will be turned off.
- To exit a mode selected input or output and moving to another, press
and by a second press leave the test mode.
The function
allows the A/C system to operate without considering
internal temperature. This function is used when it is necessary to turn on the
A/C for testing and the temperature inside the bus is not enough to allow the
A/C to work. All other protections are enabled in this mode.
Input Description
LED on
LED blinking
Pressure switches
input
Both pressure
switches are OK
(closed)
One or both pressure
switches in fail status.
Check connections and
pressure switches.
Ice sensor -
freezing of
evaporator coil
input
Ice sensor OK.
Ice sensor indicates that the
system is frozen. Check ice
sensor and connections.
Heating system
enabled -input
indicating the
heating system is
installed.
Heating board
GL-W002
available,
enabled and
operating
Heating board (GL-W002)
not installed.
Fig. 6 Test Operation Input Readings
Output
Description
Turns on blowers at low speed
Turns on blowers at medium speed
Turns on blowers at high speed
Opens air flap
Turns on fans (condenser motors)
Turns on water pump
Opens heating valve (30 %) (in case there is heating)
Opens heating valve (65 %) (in case there is heating)
Opens heating valve (99 %) (in case there is heating
Gas charge function, allows refrigeration to take place,
independently of the control conditions
Fig. 7 Test Operation Output Readings
Summary of Contents for Aerosphere World
Page 4: ...Aerosphere World Midibus IV ...
Page 22: ...Aerosphere World Midibus 18 Abb 12 Verflüssigergebläse Aerosphere World Langversion ...
Page 24: ...Aerosphere World Midibus 20 Abb 14 Verdampfergebläse Aerosphere World Kurzversion ...
Page 25: ...Aerosphere World Midibus 21 Abb 15 Verflüssigergebläse Aerosphere World Kurzversion ...
Page 28: ...Aerosphere World Midibus 24 Abb 18 Zusatz Relaistafel GL W230 Aerosphere World Langversion ...
Page 29: ...Aerosphere World Midibus 25 Abb 19 Heizungsmodul GL W003 Aerosphere World und Midibus ...
Page 30: ...Aerosphere World Midibus 26 Abb 20 Verdampfergebläse Midibus ...
Page 31: ...Aerosphere World Midibus 27 Abb 21 Verflüssigergebläse Midibus ...
Page 32: ...Aerosphere World Midibus 28 Abb 22 Relaistafel GL W540 Midibus ...
Page 49: ...Aerosphere World Midibus 45 Fig 12 Condenser Fans Aerosphere World Long Version ...
Page 51: ...Aerosphere World Midibus 47 Fig 14 Evaporator Blowers Aerosphere World Short Version ...
Page 52: ...Aerosphere World Midibus 48 Fig 15 Condenser Fans Aerosphere World Short Version ...
Page 54: ...Aerosphere World Midibus 50 Fig 17 Main Relay Board GL W530 Aerosphere World ...
Page 56: ...Aerosphere World Midibus 52 Fig 19 Heating Board GL W003 Aerosphere World and Midibus ...
Page 57: ...Aerosphere World Midibus 53 Fig 20 Evaporator Blowers Midibus ...
Page 58: ...Aerosphere World Midibus 54 Fig 21 Condenser Fans Midibus ...
Page 59: ...Aerosphere World Midibus 55 Fig 22 Main Relay Board GL W540 Midibus ...