Inadequate Power Output
Possible Source
of the Error
Test
Solution
Bad electrical
connection
• Switch BRAKE/RUN and
SHORT/RUN switches on
the controller to the BRAKE
and SHORT positions
respectively.
• Contract qualified
electrician to check
electrical connection
Replace defective electrical connections
by authorised personnel
High electric cable
resistance
Check cable cross section and
lengths with recommended
dimensions in Wiring
Specifications
Replace with higher cross section cable
Damaged blades
Check blades for visual damage
If blades are damaged,
contact [email protected]