8
The table below shows the minimum chimney height requirements, fireplace included, according to the
number of elbows:
Chimney
Number of Elbows
Minimum Height
Straight installation
---------------
15’ (4.6 m)
1 - 15° offset
2 - 15° elbows
15’ (4.6 m)
2 - 15° offsets
4 - 15° elbows
18’ (5.5 m)
1 - 30° offset
2 - 30° elbows
15’ (4.6 m)
2 - 30° offsets
4 - 30° elbows
20’ (6.1 m)
* 1 - 45° offset
* 2 - 45° elbows
16’ (4.9 m)
* 2 - 45° offsets
* 4 - 45° elbows
23’ (7.0 m)