30
2. The duct can also be safely connected to an existing heating system. However, do not connect any hot air
ducts to the cold air return. The hot air duct must be connected to the main duct coming out of the blower.
Install a back draft damper at the junction between the fireplace duct and the blower outlet duct.
ATTENTION: The connection to an existing duct must follow the direction of the furnace’s airflow and
be equipped with a back draft damper. (Figure #19)
Both alternatives require electrical power. Make sure all electrical connections are made in the correct
order and comply with local regulations as well as the applicable National Building Code standards. Install the
rheostat close to the fireplace so it can be easily closed whenever you must open the fireplace doors. If the fan is
running, the smoke will be drawn out through the doors instead of up the chimney.
ATTENTION: Keep the fireplace fan’s electrical circuitry separate from the central blower’s circuitry.
One must not control the other and vice versa.
Figure #19: Forced Air Distribution Kit
Summary of Contents for Saguency FP8
Page 7: ...7 Figure 2 Various Fireplace Locations Figure 3 Chimney Configurations...
Page 11: ...11 Figure 5 Hearth Extension Installation...
Page 15: ...15 Figure 6 Masonry chimney installation Figure 6 1 Minimum Chimney Height...
Page 18: ...18 Figure 11 Fireplace Finishing Figure 12 Mantel Positioning...
Page 19: ...19 Figure 13 Installation of Combustible and Non Combustible Materials...
Page 20: ...20 Figure 14 Chimney Enclosure...