13
INSTALLATION INSTRUCTION FOR MASONRY APPLICATION
The following requirements must be respected:
1. The chimney must be absolutely clear of any soot residue or creosote. Check for cracks, loose or missing
bricks that could inhibit correct installation of the liner.
2. The clearance to combustible must be a minimum of 1” between the outside of the masonry and any wood
framing or loose insulation.
3. The chimney must be built in accordance with the current building code.
4. No other appliance can be connected to the same chimney.
5. The clearances to combustible for the BISPMA and BISUPMA30 connectors are 2” on the side and bottom
and 16” at the top.
6. The connector parts are not necessary if the connection between the insulated length and the stainless steel
liner is done within the masonry chimney.