41
Valcom, Inc.
5614 Hollins Road
Roanoke, VA 24019
USA
P. 540-563-2000
F. 540-362-9800
www.valcom.com
Valcom, Inc.
5614 Hollins Road
Roanoke, VA 24019
USA
P. 540-563-2000
F. 540-362-9800
www.valcom.com
Manual Controls
Setting 40 - Hours Since the Last Input Signal Was Received
This setting is read-only, and will always be a value from 00 to 99. The value
represents the number of hours since the master clock received an input signal.
Setting 44 - Internet Connection Status.
This setting is read-only, and will always display a value of either 00 or 01. If the
value is 00, the master clock is not connected to the internet. If the value is 01,
the master clock is connected to the Internet.
Setting 45 - Crossover Cable
This setting has two values, “OFF” and “cr”, which can be switched by pressing
the bottom button. If OFF is selected, the master clock is configured to use
DHCP or whatever static IP has been set. If “cr” is selected, then the master
clock will prepare itself to switch to Crossover mode. To fully switch to Crossover
mode, select cr using the bottom button, press the top button to advance to
the next Setting, wait 20 seconds, then power-cycle the master clock. When the
master clock is powered again, it will be configured to a Static IP
of 192.168.0.123.
Setting 50 - Enter Secondary Clock Diagnostic Mode (Valcom Wired Only)
Use the bottom button to scroll between values “E” and “d”. Value “E” will
enable diagnostic mode for Valcom Wired clocks on the system, while value
“d” will disable diagnostic mode for Valcom Wired clocks.
Setting 51 - Send Diagnostic to Secondary Clocks (Valcom Wired Only)
Pressing the bottom button will scroll through the values 1, 2, 3, 4, 5, and 9.
Each value corresponds to a particular diagnostic. See your secondary clock
manual for details on each diagnostic.
01 - Protocol Verification.
02 - Comprehensive Test
03 - Manufacturer’s Default
04 - Combination of 02 and 03 (button must be pressed on Valcom Wired clocks)
05 - Combination of 02 and 03 (button does not need to be pressed on secondary clock)
09 - Overrides the previous Diagnostic and commands secondary clocks to resume
displaying the time.
Setting 52 - Viewing Duration for Diagnostic Results (Valcom Wired Only)
Press the bottom button to scroll from 00 to 60. Each value represents the
number of minutes that a secondary clock will display the completed diagnostic.
For instance, if a value of 30 is selected, then secondary clocks that have been
sent a diagnostic command by the master clock will continue to show the results
of their diagnostic for 30 minutes.
Pressing the top button one more time will revert the master clock LED display to showing the
time. Any altered settings will be saved to the master clock’s memory.
40--76
44--01
45--cr
50-- E
51-- 5
52--00