39
Valcom, Inc.
5614 Hollins Road
Roanoke, VA 24019
USA
P. 540-563-2000
F. 540-362-9800
www.valcom.com
Valcom, Inc.
5614 Hollins Road
Roanoke, VA 24019
USA
P. 540-563-2000
F. 540-362-9800
www.valcom.com
The numbers shown on the left are examples. Going down the list and entering every one of
the examples exactly as shown will cause the master clock to malfunction or use incorrect data.
Program your clock setting based off of the instructions in the description on the right.
Setting 9 - Clock I.D. Number
Press the bottom button to advance the ID number of the clock. This accepts
the ID numbers 1 through 999.
The ID Number is used for displaying text messages like 911, bELL, and FirE.
Consult the Master Clock manual for more information.
Setting 10 - Zone Number
Press the bottom button to advance the ID number of the clock. This accepts
the Zone Numbers 01 through 99.
The Zone Number is used for displaying text messages like 911, bELL, and FirE.
Consult the Master Clock manual for more information.
Setting 11 - Do not modify.
Do not modify this setting.
If the value is changed by accident, press the bottom button until this setting
displays option 00.
Setting 13 - Enable Loss of Communication Alert
Press the bottom button to switch between “d’ or “E”
“d” disables Loss of Communication Alert
“E” enables Loss of Communication Alert
When Loss of Communication Alert is enabled, the colons on the display will
blink if the digital clock fails to synchronize with the master clock within a set
amount of time. This amount of time is set through Setting 14.
Manual Controls (V-D110XXB Only)
11
--
01
13
--
E
9
--
1
10
-
02