 4 

 

 

 

 

 

WIRING INSTRUCTIONS:

 

__  1. 

Connect Tip of the telephone system 600 
Ohm page port to terminal 1 (TIP) of the 
V-9941A. 

__  2. 

Connect Ring of the 600 Ohm page port to 
terminal 2 (RING).  

__  3. 

Connect one side of the telephone system 
dry contact closure to terminal 3 (GND) of 
the V-9941A. 

__  4. 

Connect the other side of the contact closure 
to terminal 5 (GND ST) of the V-9941A. 

__  5. 

Connect Tip and Ring of the talkback 
speakers to the V-9941A terminals 6 and 7 
(SPKR). 

      6.      Option Switches: 
__  a. 

"SW1-1" controls the initial alert tone.  Turn 
the switch ON to precede each page with an 
audible tone. 

__  b.      "SW1-2" controls the repeated alert tone.  

Turn the switch ON to have a short tone 
burst every 15 seconds during a handsfree 
page. 

__ 7. 

Plug in power supply. 

NOTE:  "A" battery may be substituted 
for "B" battery

__  8. 

Connect -24VDC "B" battery (may be 
referred to as "-" or "signal battery") from 
power supply to terminal 4 (-24VDC) on the 
V-9941A.  

__  9. 

Connect -24VDC "B" ground ("+" or "signal 
ground") from power supply to terminal 3 
(GND). 

__ 10.  Connect -24VDC ground (+) from power 

supply to telephone system GROUND. 

__ 11.  " SW3 " turn to the OFF position (Battery 

Feed Off). 
 

 

10

9

7

8

6

5

4

3

2

1

In

hi

bit

M

us

ic

M

us

ic

Sp

kr

Sp

kr

G

nd

 S

ta

rt

-2

4V

D

C

G

ro

u

n

d

R

ing

Ti

p

Page Port

R
T

Ground (+)
-24VDC

V-9941A

45 Ohm Talkback Speaker

ELECTRONIC KEY PAGE PORT CONNECTIONS

Electronic Key System

Contact
Closure

SW1

SW3

Location of Screw Terminals,

Option Switches and Volume Controls

                      RAT
         15 Sec Tone

Initial Tone
         IATE

Phone to Speaker

Speaker to Phone

Battery Feed

V-9941A One Zone Talkback Control

10

9

7

8

6

5

4

3

2

1

In

hib

it

M

us

ic

M

us

ic

Sp

kr

Sp

kr

Gn

St

ar

t

-2

4V

DC

Gro

un

d

Ri

ng

Tip

SCREW CONNECTION DESIGNATIONS

OFF

ON

OFF

ON

Summary of Contents for V-9941A

Page 1: ...contact closure Dedicated single line telephone Refer to Figure 1 for a block diagram of a typical installation NOTE When used with additional equipment the V 9941A can also be accessed from a push to talk microphone for use in restaurant drive in windows and other similar applications Contact Valcom Application Engineering for information Features Loop start Input for ground start from a contact ...

Page 2: ...osure 1 V 9941A talkback page control 1 VP 624B power supply 45 Ohm talkback speaker maximum two Background Music The V 9941A provides background music input and is designed to automatically cut off the music during a page If background music is to be installed a receiver providing an 8 Ohm output with 1 3 Watts of output power will be required Inhibit Option The V 9941A is equipped with an inhibi...

Page 3: ...DC B battery may be referred to as or signal battery from power supply to terminal 4 24VDC on the V 9941A __ 7 Connect 24VDC B ground or signal ground from power supply to terminal 3 GND __ 8 Connect 24VDC ground from power supply to telephone system GROUND 10 9 7 8 6 5 4 3 2 1 Inhibit Music Music Spkr Spkr Gnd Start 24VDC G round Ring Tip C O Line Position or Loop Start Trunk Port R T Ground 24VD...

Page 4: ...er supply NOTE A battery may be substituted for B battery __ 8 Connect 24VDC B battery may be referred to as or signal battery from power supply to terminal 4 24VDC on the V 9941A __ 9 Connect 24VDC B ground or signal ground from power supply to terminal 3 GND __ 10 Connect 24VDC ground from power supply to telephone system GROUND __ 11 SW3 turn to the OFF position Battery Feed Off 10 9 7 8 6 5 4 ...

Page 5: ...nd Ring SW3 ON This provides Talk Battery to allow proper operation of PABX loop start trunk ports Electronic Key system line key position or a dedicated single line telephone A loop sense circuit connected with the battery feed turns on the V 9941A on access from the phone system Note By turning SW3 OFF and placing a ground on the ground start terminal the unit may be accessed Immediately after a...

Page 6: ...e validity of the claim 2 the defect is not the result of damage misuse or negligence after the original shipment 3 the product has not been altered in any way or repaired by others and that factory sealed units are unopened a service charge plus parts and labor will be applied to units defaced or physically damaged 4 freight charges for the return of products to Valcom are prepaid 5 all units out...

Page 7: ... 9941A and the second test set across terminals 6 SPKR and 7 SPKR Turn SW3 ON c While monitoring the second test set go off hook on the first test set and page d If the page is heard when the V 9941A is working verify the connections to the speakers If your system still does not work verify proper programming of your phone system There should not be any type of toll restriction on the port used to...