background image

 

 

 

   Issue 

 

1 947960 

 

 
 
 

 V-9941A 
 ONE ZONE HANDSFREE TALKBACK CONTROL UNIT

 

 
 

INTRODUCTION

 

The V-9941A is a One Zone Handsfree Page Unit for 
use on an Electronic Key system line key position, a 
PABX loop start trunk port, a dedicated single line 
telephone or a 600 Ohm two-way page port with a 
contact closure. 
 
These instructions contain the specifications and 
information necessary to install, operate and maintain 
the One Zone Handsfree Talkback Control Unit. 
 

SPECIFICATIONS

 

Purpose

 

 

Provides battery feed and loop detect circuitry to 
properly interface with a telephone system C. O. 
position or dedicated single line telephone. 

 

Provides VOX circuit and handsfree amplifier to 
drive 45 Ohm talkback speakers. 

 

Provides 600 Ohm input with ground start input  
to operate on E-Key systems with a 600 Ohm 
two- way page port and a contact closure. 

 

Applications

 

 

PABX loop start trunk port 

 

Electronic key system C. O. Line position    

 

Telephone systems with 600 Ohm two-way page 
port and contact closure 

 

Dedicated single line telephone 

 
Refer to Figure 1 for a block diagram of a typical 
installation. 

 

NOTE:  When used with additional 
equipment, the V-9941A can also be 
accessed from a push-to-talk microphone for 
use in restaurant drive-in windows and other 
similar applications.  Contact Valcom 
Application Engineering for information.
 

 
 

          

 

 
Features

 

 

Loop start 

 

Input for ground start from a contact closure 

 

Provides optional battery feed 

 

Built in talkback amplifier 

 

Directly drives up to two talkback speakers 

 

Will drive Valcom one-way amplified speaker 
assemblies 

 

Screw terminals for all connections 

 

Initial alert tone option 

 

Repeated alert tone option 

 

Music input 

 

Speaker inhibit option 

 

Operates on -24VDC "B" Battery 

 

Limitations 

 

Maximum of two Valcom talkback speakers plus 
40 one-way amplified speaker assemblies. 

 

Maximum allowable cable distance from control 
unit to talkback speakers is 800 feet. 

 

Capacity

 

 

Each V-9941A will provide one zone of talkback 
paging 

 

The V-9941A is a single talk path unit 

 

Each V-9941A will drive up to two 45 Ohm 
talkback speakers 

 

Up to 40 one-way amplified speaker assemblies 
may be used in addition to the talkback speakers 

 

Summary of Contents for V-9941A

Page 1: ...contact closure Dedicated single line telephone Refer to Figure 1 for a block diagram of a typical installation NOTE When used with additional equipment the V 9941A can also be accessed from a push to talk microphone for use in restaurant drive in windows and other similar applications Contact Valcom Application Engineering for information Features Loop start Input for ground start from a contact ...

Page 2: ...osure 1 V 9941A talkback page control 1 VP 624B power supply 45 Ohm talkback speaker maximum two Background Music The V 9941A provides background music input and is designed to automatically cut off the music during a page If background music is to be installed a receiver providing an 8 Ohm output with 1 3 Watts of output power will be required Inhibit Option The V 9941A is equipped with an inhibi...

Page 3: ...DC B battery may be referred to as or signal battery from power supply to terminal 4 24VDC on the V 9941A __ 7 Connect 24VDC B ground or signal ground from power supply to terminal 3 GND __ 8 Connect 24VDC ground from power supply to telephone system GROUND 10 9 7 8 6 5 4 3 2 1 Inhibit Music Music Spkr Spkr Gnd Start 24VDC G round Ring Tip C O Line Position or Loop Start Trunk Port R T Ground 24VD...

Page 4: ...er supply NOTE A battery may be substituted for B battery __ 8 Connect 24VDC B battery may be referred to as or signal battery from power supply to terminal 4 24VDC on the V 9941A __ 9 Connect 24VDC B ground or signal ground from power supply to terminal 3 GND __ 10 Connect 24VDC ground from power supply to telephone system GROUND __ 11 SW3 turn to the OFF position Battery Feed Off 10 9 7 8 6 5 4 ...

Page 5: ...nd Ring SW3 ON This provides Talk Battery to allow proper operation of PABX loop start trunk ports Electronic Key system line key position or a dedicated single line telephone A loop sense circuit connected with the battery feed turns on the V 9941A on access from the phone system Note By turning SW3 OFF and placing a ground on the ground start terminal the unit may be accessed Immediately after a...

Page 6: ...e validity of the claim 2 the defect is not the result of damage misuse or negligence after the original shipment 3 the product has not been altered in any way or repaired by others and that factory sealed units are unopened a service charge plus parts and labor will be applied to units defaced or physically damaged 4 freight charges for the return of products to Valcom are prepaid 5 all units out...

Page 7: ... 9941A and the second test set across terminals 6 SPKR and 7 SPKR Turn SW3 ON c While monitoring the second test set go off hook on the first test set and page d If the page is heard when the V 9941A is working verify the connections to the speakers If your system still does not work verify proper programming of your phone system There should not be any type of toll restriction on the port used to...