5
VALCOM LIMITED WARRANTY
Valcom, Inc. warrants its products to be free from defects in materials and workmanship under conditions of normal use and service
for a period of one year from the date of shipment. The obligation under this warranty shall be limited to the replacement, repair or
refund of any such defective device within the warranty period, provided that:
1.
inspection by Valcom, Inc. indicates the validity of the claim;
2.
the defect is not the result of damage, misuse, or negligence after the original shipment;
3.
the product has not been altered in any way or repaired by others and that factory sealed units are unopened (a service
charge plus parts and labor will be applied to units defaced or physically damaged);
4.
freight charges for the return of products to Valcom are prepaid;
5.
all units ‘out of warranty’ are subject to a service charge. The service charge will cover minor repairs (major repairs will
be subject to additional charges for parts and labor).
This warranty is in lieu of and excludes all other warranties, expressed or implied and in no event shall Valcom, Inc. be
liable for any anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connection
with the purchase, operation, or use of the product.
This warranty specifically excludes damage incurred in shipment. In the event a product is received in damaged condition, the
carrier should be notified immediately. Claims for such damage should be filed with the carrier involved in accordance with the
F.O.B. point.
Headquarters:
In Canada
Valcom, Inc.
CMX Corporation
5614 Hollins Road
35 Van Kirk Drive #11 and 12
Roanoke, VA 24019-5056
Brampton, Ontario L7A 1A5
Phone: (540) 563-2000
Phone: (905) 456-1072
FAX: (540) 362-9800
FAX: (905) 456-2269
1T IN
1R IN
1T OUT
1R OUT
2T IN
2R IN
2T OUT
2R OUT
3T IN
3R IN
3T OUT
3R OUT
RING
DETECTION
TONE
GENERATION
C1
.22mf
11,26
12,27
13,28
ZONE 1
ZONE 2
ZONE 3
14,29
15,30
GND
POW ER
SUPPLY
PIN NUMBERS ON
CROSSCONNECT BLOCK
-24VDC
R16
VOLUME
ZONE 3
R12
VOLUME
ZONE 2
R8
VOLUME
ZONE 1
K3
K3
16
17
1
2
18
19
K2
K2
3
4
K1
K1
20
21
5
6
R1
FIGURE 4 - SIMPLIFIED SCHEMATIC
BUZZER
RINGING
RINGING OR
BUZZER
COMMON
-24VDC
"B BATT"
UNA OR RING
DRY CLOSURE
7
22
PITCH
25 AUX 1 NO
23 AUX 1 COM
AUX 1 NC
24
AUX 2 NO
8 AUX 2 COM
AUX 2 NC
9
10