background image

E-Key
C.O.Line
Position

  V-2904
Universal
Four Door
Answering
  System

Doorplate
Speaker
with
Pushbutton

Up to 4
Locations

   FIGURE 1 - SIMPLIFIED BLOCK DIAGRAM OF A TYPICAL INSTALLATION

Power
Supply

 

 
 
 

Features 

• 

Compatible with PABX, E-Key and 1A2 
telephone 

• 

Switch selectable - loop or ground start access 

• 

Provides handsfree talkback to four separate  
locations 

• 

RJ11 modular connector for Tip and Ring 
connections 

• 

Power ON LED 

• 

Provides contacts for up to four circuits 

• 

Programmable options: 

Programming access code 
Ring Pattern 
Station Identification 
Activate lock relay 
Duration of lock relay activation 
Time door can remain open after unlock 
(exit delay time)  
Entry delay time 
Number of ring cycles 
Disable station alarm 
Alarm disable code  
Station alert tone 

• 

Input for manual door unlock (push button) 

• 

Built-in 30Hz ring voltage generator with on/off 
switch 

• 

Ringback tone to speaker 

• 

Calls can be placed On Hold 

• 

Call waiting 

• 

One-way all call with volume control 

• 

Background music input with volume control 

• 

Speaker to phone volume control 

• 

Phone to speaker volume control 

• 

Simultaneous calls placed in queue 

• 

Dial tone 

• 

Confirmation tone 

• 

Compatible with tone dial phones 

• 

Works with Valcom V-1072A doorplate speaker 
or other Valcom one-way or talkback speakers. 

• 

Compatible with VPB-260 battery backup 

  

Dimensions/Weight 

Dimensions:   8.60" H x 11.00" W x 2.30" D 
 

(21.84cm H x 27.94cm W x 5.84cm D) 

Weight:          3.1 lbs. (1.41 kg) 
 

Nominal Specifications 

Input Impedance: 

600 Ohms 

Input Level: 

-10dBm Nominal 

Output Impedance: 

45 Ohms 

Ring Supply: 

90VAC, 30Hz 

Suitable for REN of 5.0 
 

Power Requirements 

Power Supply: 

-24VDC filtered 

 600mA 

minimum 

 

Environment 

Temperature: 

0 to 40°C 

Humidity: 

0 to 85% (non-precipitating) 

 

 2 

 

Summary of Contents for V-2904

Page 1: ...rent branch circuit FCC Notice This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the instructions listed in this User s...

Page 2: ...alert tone Input for manual door unlock push button Built in 30Hz ring voltage generator with on off switch Ringback tone to speaker Calls can be placed On Hold Call waiting One way all call with vol...

Page 3: ...to close Example Station 3 ring ring ring If the phone is off hook any activity the phone is involved in will be terminated and the phone will receive a momentary warble tone a station indication tone...

Page 4: ...em is to ring when the door button is pressed Refer to Figure 3 for location ___ 6 Connect the 24VDC power supply 24VDC should be connected to pin 25 S V and Ground connected to pin 50 V S The power L...

Page 5: ...ck Make Door 1 Unlock Stationary Door 1 Unlock Break Station 1 Handsfree Speaker 1 Tip Handsfree Speaker 1 Ring Door Button 1 Remote 1 Door Sensor 1 Ground 1 Door 2 Unlock Make Door 2 Unlock Stationar...

Page 6: ...eaker with Pushbutton 66 Block V 1072A Handsfree Talkback 45 Ohm Speaker with Pushbutton Door 1 Unlock Make W S P 30 Door 1 Unlock Stationary S W P 5 Door 1 Unlock Break R BL P 31 NO Com Electric Stri...

Page 7: ...ment Customer Provided Magnetic Door Switch Figure 9 Door Sensor Unauthorized Door Opening GR W P 3 66 Block Equipment Customer Provided Figure 10 Unauthorized Door Opening 24VDC Alarm To Alarm auto d...

Page 8: ...rformed with a tone dial set The V 2904 is designed to allow the user to program its functions to meet the requirements of the specific application The V 2904 is however shipped from the factory with...

Page 9: ...until the end of the second burst To change this default setting 1 Lift handset and hear dial tone 2 Press 1 2 3 6 on the dial pad Station Identification 3 Enter station number 1 4 or for all station...

Page 10: ...contacts are closed when the door is closed and some are open when the door is closed By default the V 2904 uses door alarm contacts that are open when the door is closed Disable Station Alarm On powe...

Page 11: ...door unlock Call Waiting If the phone is connected to station 1 in a conversation and station 2 attempts by pressing the door button to call in the individual at the phone will receive a call waiting...

Page 12: ...ities in Roanoke VA Should repairs be necessary attach a tag to the unit clearly stating your company name address phone number contact person and the nature of the problem Send the unit to Valcom Inc...

Page 13: ...defect is not the result of damage misuse or negligence after the original shipment 3 the product has not been altered in any way or repaired by others and that factory sealed units are unopened a ser...

Page 14: ..._ Sta 2 MAC 82________ Sta 3 MAC 83________ Sta 4 MAC 84________ All Doors MAC 8 _____ 0 999 in seconds Sta 1 Sta 2 Sta 3 Sta 4 Duration of Ringing Sta 1 Sta 2 Sta 3 Sta 4 30 sec 30 sec 30 sec 30 sec...

Reviews: