INSTALLATION

Precautions

All precautions have been taken at the factory to
insure that the equipment functions properly when
installed correctly.  Please observe the following
precautions before applying power to the equipment
or the equipment may be damaged and the warranty
voided.

 

Unplug the power supply before making any
connections to the control unit.

 

Do not locate the control unit closer than 18
inches or further than 5 feet from the power
supply.

 

Do not use a lamp tester to check signals, use a
voltmeter.  A lamp tester when first applied is a
short circuit to electronic circuits.

 

Do not apply power to the control unit until all
connections have been double-checked.

Mounting

Mount the V-136RT on a 7" KTU mounting, relay
rack or on the wall.

Connections

 

Fasten a 25 pair cable to the unit and terminate
all leads on a 66 type block per Figure 1, 2 or 3.

 

Strap 1 ground, B ground, lamp ground, 18 Vac
and 105 Vac signal grounds common at power
supply.

 

Refer to Figure 1 for connections; use the chart
in Figure 1 to set the option programming.

NOTE: Option switches 3 and 4 must be in the off

position for proper operation with bells or
buzzers.

 

Refer to Figure 2 for connections for 36 stations
of buzzer signalling.  This figure may also be
used for 36 stations of bell signalling by
replacing the      18 Vac buzz voltage with 105
Vac ring voltage.

 

Refer to Figure 3 for connections for mixed
signalling with 20 stations of bells and 16
stations of buzzers.

OPERATION

To make an intercom call, go off-hook and dial the
number of the desired station.  Dial tone will be
broken after the first number is dialed.  A one second
ringback tone will indicate that the called station is

being signalled.

To rering the same station, press the "*" button.  The
station will be signalled as long as the * button is
held.  To rering rotary, dial "1".  The station will be
signalled for one second each time a "1" is dialed.

For conference calling (tone only), dial the first
station number, press the "#" button to receive dial
tone, then dial the next station number.

General Method of Operation

When the calling party goes off-hook, the switch
hook contacts in the telephone set close the tip and
ring to form a loop.  Loop closure detection logic
then operates the lamps at all stations and returns dial
tone to the telephone set.  Dial detection circuitry will
then receive dialing information and operate relays
and/or circuitry to supply signalling voltage to the
desired station.

TECHNICAL ASSISTANCE

When trouble is reported, verify that:

 

All telephone sets are in proper working order

 

Power is being supplied to the unit

 

There are no broken connections at the
connecting block

 

The conductors of color coded cables are
terminated in the proper order

If trouble still exists, additional checks should be
made using the following equipment:

 

Voltmeter

 

Tone-dial single-line instrument (for tone-dial
systems)

 

Telephone Test Set

 

Clip leads

Before proceeding further, check the voltages at the
connecting block.  An undetected blown fuse or low
voltage will cause improper control operation.  DC
voltage measurements are made with respect to (+)
ground.

If a spare unit is available, continue to troubleshoot
by substituting the spare unit for the suspected unit.

If the trouble has not been located, refer to the
Troubleshooting Chart.  Identify the symptoms and
perform the corrective actions indicated.  After all the
suggested tests have been performed, the trouble still
exists, call Valcom at (540) 427-3900 and ask for

Summary of Contents for V-136RT

Page 1: ...vits filed with the telephone company it will be also be recorded in the system log kept by installation and maintenance personnel The local telephone company is to be notified when this intercom unit...

Page 2: ...tone will indicate that the called station is being signalled To rering the same station press the button The station will be signalled as long as the button is held To rering rotary dial 1 The stati...

Page 3: ...se and service for a period of one year from the date of shipment The obligation under this warranty shall be limited to the replacement repair or refund of any such defective device within the warran...

Page 4: ...4 947136 Valcom Inc CMX Corporation 1111 Industry Avenue 35 Van Kirk Drive 11 and 12 Roanoke VA 24013 Brampton Ontario L7A1A5 Phone 540 427 3900 Phone 905 456 1072 FAX 540 427 3517 FAX 905 456 2269...

Page 5: ...RN ICM KEYS POWER SUPPLY ICM KEYS PAGE CONTROL AUDIBLE SIGNAL POWER SUPPLY NOTES 1 BELL BUZZER GROUP ONE STATIONS 10 29 2 BELL BUZZER GROUP TWO STATIONS 30 39 0 5 9 3 AUDIBLE SIGNAL 18VAC BUZZ OR 105V...

Page 6: ...S23 S24 S25 S26 S27 S28 S29 S30 S31 S32 S33 S34 S35 S36 S37 S38 S39 S0 S5 S6 S7 S8 S9 S1 IN S2 IN AG AB BG BB R10 R11 R12 R13 R14 R15 R16 R17 R18 R19 R20 R21 R22 R23 R24 R25 R26 R27 R28 R29 R30 R31 R3...

Page 7: ...30 S31 S32 S33 S34 S35 S36 S37 S38 S39 S0 S5 S6 S7 S8 S9 S1 IN S2 IN AG AB BG BB R10 R11 R12 R13 R14 R15 R16 R17 R18 R19 R20 R21 R22 R23 R24 R25 R26 R27 R28 R29 R30 R31 R32 R33 R34 R35 R36 R37 R38 R39...

Page 8: ...MICRO PROCESSOR MEMORY DIAL PULSE DETECTOR K1 K2 K11 POWER SUPPLY BB BG LAMP SUP K11 LAMP STA 9 STA 8 STA 31 STA 30 STA 29 STA 28 STA 11 STA10 SIG IN 1 V 136RT SIMPLIFIED SCHEMATIC PC SIG IN 2 K3 K4 K...

Reviews: