background image

2

947114

Mounting

Mount the V-1134 close to the V-136RTHF control
unit allowing enough room for the amphenol
connectors.  NOTE:  The cable supplied with the unit is
30" long.  If units are separated by more than 30",
additional cable may be required.

Cabling

NOTE:  In a mixed system of Bell/Buzzer and
voice signaling, stations 30-29, 0, and 5-9
must be voice signaling.  Bells or buzzers
must be connected as excluded speakers 
(See Figure 2).

a)  In a new installation, complete all steps of the
     installation procedure as shown in the instruct-
     ions for the V-136RTHF, combination.
     Connect the 25 pair intercom cable from the 66
     type split block to the amphenol on the V-1134
     marked "to 66 block."
b)  In an existing  system without all call, remove the
     intercom cable from  the V-136RTHF and plug it
     into the amphenol on the V-1134 marked "to 66
     block."
c)  If all speakers are to receive all call, refer to
     Figure 1.  One end of the 30" cable supplied with
     the V-1134 should be plugged into the amphenol
     marked "to intercom."  The other end should plug
     into the V-136RTHF intercom unit.
d)  If some stations are to be excluded from the all
     call, refer to Figure 2.  Punch down two 25
     pair female amphenol ended cables on a 66 type
     solid block.  Plug one cable to the V-1134 "to
     intercom" amphenol and plug the second cable to
     the V-136RTHF.  Connect excluded speakers to
     the appropriate ICM number on the solid block
     and to the common speaker return on the split
     block.  Connect non-excluded speakers as shown
     in the V-136RTHF installation instruction.

NOTE:  Do not connect speakers to stations 0
or 39.

Cross Connections

a)  If  using the V-1134 with the V-136RTHF,
     perform the following:

 

Strap the Y/BN  to the  G/V on the "to 66 block"
25 pair cable.

Power Connections

The V-1134 requires no external power connections as
its power is derived from the power supplied to

the V-136RTHF.  Care should be taken to make sure
that the power supply is capable of supplying the
increased current requirements when the V-1134 is in
use.

OPERATION

When the calling party goes off hook on the intercom
and dials "0", the intercom switching network closes a
contact for station "0".  This contact connects a
resistive ground supplied by the Y/BN lead of the
V-1134 (ICM connector) back to the O/V lead of the
V-1134 (ICM connector).  The V-1134 operates a
series of relays with transfer contacts and all stations
are transferred to the outputs of audio amplifiers.  After
approximately 1 second the amplifiers  are energized
and the calling party can make a one-way page to all
stations.  If station "0" is not dialed, the V-136RTHF
units perform in the manner described in their Valcom
System Instructions with the speaker leads from the
control units going straight through normally  closed 
contacts  in  the  V-1134.

TECHNICAL ASSISTANCE

When trouble is reported, verify that power is being
supplied to the unit and there are no broken
connections.  Check voltages for proper polarity on the
crossconnect block.  The table on the next page
identifies symptoms of some possible problems with
solutions. 

If a spare unit is available, continue to troubleshoot by
substituting the spare unit for the suspected unit.

Assistance in troubleshooting is available from the
factory.  When calling, you should have a VOM, a
telephone test set, several clip leads available and be
calling from the job site.  Call (540) 427-3900 and ask
for Technical Support, or call (540) 427-6000 for
Valcom Automated Support or visit our website at
http://www.valcom.com.

The V-1134 is not field repairable.  Valcom, Inc.
maintains service facilities in Roanoke, VA.  Should
repairs be necessary, attach a tag indicating company
name, address, phone number, contact person, and the
nature of the problem.  Send the unit to:

Valcom, Inc.

Repair and Return Dept.

5614 Hollins Road

Roanoke, VA  24019-5056

Summary of Contents for V-1134

Page 1: ...ements 24 Vdc B battery 1 amp maximum Output 400 milliwatts per speaker DESIGN General This unit provides one way all call page to the V 136RTHF The functions and operation of the intercom unit remain the same as without the all call unit with exception that dialing 0 energizes the all call unit and permits a one way page to all stations of the intercom INSTALLATION Precautions All precautions hav...

Page 2: ... is derived from the power supplied to the V 136RTHF Care should be taken to make sure that the power supply is capable of supplying the increased current requirements when the V 1134 is in use OPERATION When the calling party goes off hook on the intercom and dials 0 the intercom switching network closes a contact for station 0 This contact connects a resistive ground supplied by the Y BN lead of...

Page 3: ...ify straps are in place on crossconnect field Verify that a 5K ohm resistive ground appears at the W G pin 28 wire of the to 66 block cable when two or more phones are off hook on the intercom Refer to the V 136RTHF instruction Adjust all call volume on unit to desired listening level Ground on a speaker wire Remove all speaker cables at main frame Reconnect one at a time and test V 136 RTHF V 113...

Page 4: ...n the event a product is received in damaged condition the carrier should be notified immediately Claims for such damage should be filed with the carrier involved in accordance with the F O B point Headquarters In Canada Valcom Inc CMX Corporation 1111 Industry Avenue 35 Van Kirk Drive 11 and 12 Roanoke VA 24013 Brampton Ontario L7A1A5 Phone 540 427 3900 Phone 905 456 1072 FAX 540 427 3517 FAX 905...