background image

 

 

 

 

                                                                               

Precautions 

All precautions have been taken at the factory to 
insure that the equipment functions properly.  To 
insure proper operation and to prevent equipment 
damage, please observe the following: 

 

• 

Unplug the power supply before  making any 
connections to the control unit. 

 
 
 
 
 
 

• 

Do not locate the control unit closer than 18 
inches or further than five feet from the power 
supply. 

• 

Do not use a lamp tester to check signals, use a 
voltmeter.  A lamp tester when first applies is a 
short circuit to electronic circuits. 

• 

Do not apply power to the control unit until all 
connections have been checked. 

 

Mounting 

Mount the unit in a vacant space in an equipment 
cabinet, rack or key system cabinet, allowing enough 
room at the rear of the unit to plug in an amphenol 
connector.  Mount a 66B type punchdown block near 
the unit and label it per Figure 2. 
 

Cabling 

A 25 pair cable with a female connector should be ran 
from the unit to the connection block.  The cable 
should be terminated on the connection block in 
standard color code order.  Verify that the 
connections are correct prior to plugging the other 
end of the cable into the V-1109RTHF Page Unit. 
 

Connections to PABX System 

The V-1109RTHF may be accessed by connecting the 
W/BL and BL/W to the Tip and Ring, respectively, of 
a Loop Start Trunk Circuit.  Refer to Figure 3 for 
connections. 
 

Connections to Electronic Key 
Systems 

The V-1109RTHF may be accessed by a C.O. line 
position of an Electronic Key System by connecting 
the W/BL, BL/W of the V-1109RTHF to a spare line 
position of the Electronic Key.  This line position 
must be equipped with a trunk card.  Refer to Figure 3 
for connections. 
 

Connections to 1A2 Key System 

The V-1109RTHF may be connected to a spare button 

of a 1A2 Key Telephone by making the following 
connections 

(a 400 type line card is not needed in 

this application):

 

 

• 

W/BL, BL/W of V-1109RTHF to spare button Tip 
and Ring.  Refer to Figure 4 for connections. 

• 

O/W to Lamp Lead of spare button for lamp 
connections.  Refer to Figure 4 for connections. 

NOTE:  For 

Meet Me Page

 on 1A2, connect A -Leads 

from spare button using 10K Ohm resistors in series 
with each A-Lead.  The other side of resistors are 
connected to the BK/G (inhibit) of V-1109RTHF.  
Refer to Figure 6 for connections. 
 
 
 
 
 

Power Connections 

• 

The V-1109RTHF is designed to use -24VDC 
battery 

• 

Connect the V/BR lead to Talk Ground 

• 

Connect the BR/V lead to Talk Battery (-24VDC 
filtered). 

• 

Connect the V/S lead to Signal Ground 

• 

Connect the S/V lead to Signal Battery (-24VDC 
unfiltered) 

 
NOTE:  When the V-1109RTHF is connected to a 1A2 
Key System, connect W/O to 10VAC lamp battery.  
Refer to Figure 5 for connections. 
 
NOTE:  When the V-1109RTHF is connected to a Key 
System power supply, all grounds should be common 
and connect to an eart h ground, i.e., cold water pipe. 
 

Speaker Connections 

The output for paging zones start at the BK/BR pair 
(zone 1) through the V/O pair (zone 9).  Refer to Figure 
4 for typical speaker connections using Valcom 45 
Ohm Talkback speakers.  

No more than two 45 Ohm 

Talkback speakers may be connected to a zone.

 

 
NOTE:  All speakers should be connected with 
twisted pair, including cross-connections. 
 

Music Connections 

The output of a tuner or receiver may be connected to 
the V/G pair of the V-1109RTHF to provide 
system-wide background music. 
 
NOTE:  A low level (0.25vrms) 8 to 600 Ohm source 
should be used.  

Do not

 connect the output of a high 

power amplifier to this input. 
 

Summary of Contents for V-1109RTHF

Page 1: ...uctions may cause interference to radio and television reception It has been tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Subpart...

Page 2: ...26VDC 60mA Signal Battery 21 5 to 25VDC 250mA Lamp Battery 9 to 11VAC 45mA Lamp Remember when working with telephone equipment that BATTERY is NEGATIVE and GROUND is POSITIVE DESIGN Telephone System R...

Page 3: ...k card Refer to Figure 3 for connections Connections to 1A2 Key System The V 1109RTHF may be connected to a spare button of a 1A2 Key Telephone by making the following connections a 400 type line card...

Page 4: ...PK TO PHONE TURN CLOCKWISE TO INCREASE RECEIVE VOLUME PHONE TO SPK TURN CLOCKWISE TO INCREASE TRANSMIT VOLUME Figure 7 User Control Locations OPERATION General Description To make a voice page go off...

Page 5: ...ll close the Tip and Ring to form a loop Loop sense circuitry then operates relay and logic circuits and returns dial tone and lamp battery to the telephone set The logic circuit receives dialing info...

Page 6: ...R G G R R BR BR R R S S R BK BL BL BK BK O O BK BK G G BK BK BR BR BK BK S S BK Y BL BL Y Y O O Y Y G G Y Y BR BR Y Y S S Y V BL BL V V O O V V G G V V BR BR V V S S V A B C D E F V 1109RTHF CONNECTI...

Page 7: ...CTINGBLOCK T R PABX LOOPSTART TRUNKPORT OR E KEY C O BUTTON POSITION BB BG AB AG SPK9 RET SPK2 RET SPK1 RET LED 9 LED 1 VALCOM VP 624 POWERSUPPLY COLD WATERPIPE GROUND T R T R 45OHM TALKBACK SPEAKER W...

Page 8: ...R T R 45OHM TALKBACK SPEAKER NOTE 1 NOTES NO MORE THAN 2 TALKBACK SPEAKERS PER ZONE ELECTRICAL DEFINITIONS AG TALK GROUND AB 24VDC TALK BATTERY FILTERED 24VDC BG SIGNAL GROUND BB SIGNAL BATTERY NON F...

Page 9: ...SPK SPK BLOCK DIAGRAM OF LAMP CONNECTIONS T R LS L SPK SPK SPK SPK T R A L LG SPK SPK POWER SUPPLY 10VAC LAMP SUPPLY LAMP GROUND Connect lamp ground leads from telephone ICM buttons to lamp ground ter...

Page 10: ...oss center of block Strap individual rows together on right side of block and jumper to inhibit lead of Valcom ICM T R A L SPK SPK BLOCK DIAGRAM OF A LEAD CONNECTIONS T R L SPK SPK SPK SPK T R A L SPK...

Page 11: ...inhibit input Background music distorted Music source level too high Refer to Music Setup Section VALCOM LIMITED WARRANTY Valcom Inc warrants its products to be free from defects in materials and wor...

Page 12: ...12 FAX 540 362 9800 FAX 905 456 2269...

Page 13: ...K10 LAMP SUPPLY LAMP POWER SUPPLY B GROUND B BATTERY LED CONTROL LED 1 LED 2 LED 9 MUSIC CONTROL MUSIC IN MUSIC IN ALL CALL CONTROL K0 K0 1 5 6 9 AMP AMP SPK 9 RET 9 SPK 8 RET 8 SPK 7 RET 7 SPK 6 RET...

Reviews: