947037

 

 

Table 2 

Maximum Number of Horns 

per 

Power

 Run 

Wire Run in Feet 

(22 AWG) 

 

# Horns 

100 2 
200 1 
400 0 

TECHNICAL ASSISTANCE

 

When trouble is reported, verify that power is 
being supplied to the unit and there are no 
broken connections.  Check voltages for proper 
polarity on the cross connect block. 
 
Assistance in troubleshooting is available from 
the factory.  When calling, you should have a 
VOM, a telephone test set, and several clip leads 
available and be calling from the job site.  Call 
(540) 563-2000 and ask for Technical Support or 
visit our website at http://www.valcom.com. 
 
Valcom equipment is not field repairable.  
Valcom, Inc. maintains service facilities in 
Roanoke, VA.  Should repairs be necessary, 
attach a tag to the unit clearly stating company 
name, address, phone number, contact person, 
and the nature of the problem.  Send the unit to: 
 

Valcom, Inc. 

Repair and Return Dept. 

5614 Hollins Road 

Roanoke, VA  24019-5056

 

 
 

 

 

TROUBLESHOOTING CHART 

 

 
SYMPTOM 

 
SOLUTION 

 
No output 

 
1.  Verify –24 VDC on the white lead with ground (+) on the black. 
2.  Verify audio is present on the input and output of the V-1092 and at the 

speaker. 

3.  Verify volume control is turned up (clockwise). 
 

 
 
 
 
 

Brown
Red
Black
White

V-1039A

T Out
R Out

T In
R In

Tip
Ring
Ground

-24VDC

Page Control
Audio Output

Power Supply

V-1092

Volume Control

V-1039A CONNECTION DIAGRAM

FIGURE 2