background image

11

Connectivity Definitions

The 

Dry Loop 600 Ohm

 is a four wire interface consisting of a dry audio pair with a 600 Ohm impedance and a control

pair. The page input is activated when the control pair receives a contact closure from the host equipment, connecting Cl
to ground. The Dry Loop page input can also be activated by the presence of page input audio signals that exceed a set
threshold. This threshold is set by the page VOX adjustment; clockwise rotation lowers the threshold and makes T/R
more sensitive. Adjust by experimentation to account for various line loss and noise. This feature is beneficial for (Ampli-
fied) microphone sources that don’t have a Music/Page control contact or for Page Audio from Page Port without a
control contact closure pair.

Dry Loop Hi Impedance 

is used to interface with parallel multiple Amplicenters. Input impedance is 10K Ohms. Other-

wise, the same as the 600 Ohm dry loop operation.

The 

Ground Start

 mode is a two wire interface and has a 600 Ohm input impedance. When a trunk is accessed, a

momentary ground is sent to the ringside of the pair by the host equipment, loop current is detected and the tip-side of
the pair is closed. Disconnect supervision of the ground start mode is accomplished by monitoring the loop current.

Note: Ground start interface requires common ground between Amplicenter and telephone system by direct line or other
common grounding methods.

The 

Loop Start

 mode is two wire interface and has a 600 Ohm input impedance. The host equipment draws loop current

from the talk battery which is supplied by the AmpliCenter. Disconnect supervision of the loop start mode is accomplished
by monitoring the loop current.

TECHNICAL ASSISTANCE

When calling, have a VOM and a telephone test set available and call from the job site.  Call (540) 563-2000 and press 1
for PagePac Technical Support or visit our websites at http://www.pagepac.com and  www.valcom.com.

Should repairs be necessary, attach a tag to the unit clearly stating company name, address, phone number, contact
person and the nature of the problem.

Send the unit to:

Valcom, Inc.

PagePac

®

 Repair Dept.

5614 Hollins Road

Roanoke, VA  24019-5056

Summary of Contents for PagePac Plus AmpliCenter D100A

Page 1: ...y use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use cau...

Page 2: ...t least four inches space above and below for proper ventilation PRIOR TO TURNING ON POWER CHECK SPEAKER WIRING MAKE SURE WITH AN IMPEDANCE METER THAT FROM EITHER SPEAKER WIRE TO CONDUIT BUILDING GROU...

Page 3: ...more than one speaker cable is routed to the AmpliCenter a connector block may be necessary Refer to sample wiring diagrams page 9 Figure 11 Consult the 70V wire gauge guide page 4 Figure 5 for more s...

Page 4: ...ined output in watts for all speakers on a line Find that value at the bottom of the chart Follow the nearest vertical line up to its intersection with a diagonal wire size line Follow the horizontal...

Page 5: ...hone system With a microphone and preamp hook the mic switch to C1 and Gnd and the microphone output to Tip and Ring Note Mic requires V 9939A for preamp and contact closure Figure 7 Host Telephone Sy...

Page 6: ...e in a normal manner Your voice should be heard from all connected speakers The AmpliCenter Page input has an automatic level control ALC which keeps loud voices and normal voices output at the same l...

Page 7: ...witch not set correctly for host telephone system Ground start Tip and Ring reversed or AmpliCenter not grounded Audio signal not reaching speakers Check wiring at AmpliCenter Verify Page Accessed LED...

Page 8: ...able from 50Hz Full CCW to 400Hz Full CW 5 Music In Left and or Right channels with ground Paging In redundant paging input same as page in RJ11 Ground C1 Tip and Ring 70V Out Balanced output used for...

Page 9: ...run with an ohmmeter Any pair indicating a value of less than 16 Ohms D300A 49 Ohms D100A and 122 Ohms D40 must be rechecked for possible shorted wiring or speakers Correct any problems and retest pri...

Page 10: ...es the interconnection of two or more AmpliCenters Figure 12 AmpliCenter Interface with PagePac Plus Controller V 5323100 Note If the AmpliCenter is used with the PagePac Plus Controller refer to the...

Page 11: ...has a 600 Ohm input impedance When a trunk is accessed a momentary ground is sent to the ringside of the pair by the host equipment loop current is detected and the tip side of the pair is closed Dis...

Page 12: ...and Noise Less than 8dB below rated output 20Hz to 20kHz bandwidth unweighted Telephone Paging Access Automatic Level Control 15 1 compression ratio above 15dBm input Gain Below Limiting Knee 56dB AL...