background image

Page 5 

Valcom 12” & 16”  Wireless Clock Installation Manual 

(Rev 1.02)

 

Valcom  5614 Hollins Road    Roanoke, VA 24019    Phone: (540) 563-2000

   

Fax: (540) 362-9800   www.valcom.com

 

There are four (4) ways to install Valcom’s Analog Wireless Clock system. The user can choose 
any of the combinations listed below, or any combination of the three (3). 

 
Option #1: 
There is a main high powered transceiver in the building (V-WMCA) and repeaters (V-
WMCRA) as needed to cover the entire premise. In this option, the system does not depend 
on the slave clocks for transmission. 
 
 Option #2: 
There is at least one (1) high powered transceiver (V-WMCA) in the building and in order to 
cover the entire premise, the 

battery

-operated clocks are used as transceivers/repeaters. 

 
Option #3: 
There is at least one (1) high powered transceiver (V-WMCA) in the building and in order to 
cover the entire premise, the 

power (24V or 110V)

 operated clocks are used as transceiv-

ers/repeaters. 
 
Option #4: 
There are multiple transmitters that will cover the entire building or campus. 

Operational Instructions 

Valcom  5614 Hollins Road    Roanoke, VA 24019    Phone: (540) 563-2000

   

Fax: (540) 362-9800   www.valcom.com

 

IMPORTANT:  We highly recommend installing the main transceiver (V-WMCA) before the 
installation of the Valcom Wireless analog clocks.   

 

In order to install the clock, simply remove the battery cover, and install two (2) D cell batteries 
(recommended battery type: Duracell

®

 PROCELL

®

).  After installation of the batteries, replace the 

battery cover and the clock should start correcting within five (5) minutes.

 

 

Normal Mode/Economy Mode 

 

The Valcom Wireless Analog Series clocks have two (2) different modes in which they will operate.  
Normal mode allows the clock to transmit/receive every two (2) hours.  This mode will allow the 
clock to have a 5 year battery life (provided good reception).  Economical mode allows the clock to 
transmit/receive every four (4) hours.  This mode will allow the clock to have a 8 year battery life 
(provided good reception). 
 
Normal mode is defaulted when shipped from the factory.   
 
To toggle this mode, push and release the Diagnostic Switch and the Transmit/Receive switch si-
multaneously.  If 5 year mode is selected, the LED will be solid RED for one minute and the second 
hand will go to 5 (25 seconds).  If 8 year mode is selected, the LED will be solid GREEN for one 
minute and the second hand will go to 8 (40 seconds). 
 

IMPORTANT:  If a clock is being added to an existing system (existing clocks date coded 
prior to December 2009), it must be in normal mode. 

Summary of Contents for 12"

Page 1: ...ge 2 Double Mount Installation Page 3 WIRING INFORMATION Wiring Information Page 4 OPERATION Operational Instructions Pages 5 6 FREQUENTLY ASKED QUESTIONS Frequently Asked Questions Page 7 TROUBLESHOO...

Page 2: ...ert the sheet metal screws 10 through the mounting bracket into the plastic anchors 4 Plug the connector into the movement 110V or 24V ONLY 5 Hang the clock on the mounting bracket 6 Put the screw 4mm...

Page 3: ...nsert the wires through the mounting bracket 110V or 24V ONLY 3 Route the wires through the clock hanging rod 4 Secure hanging rod to mounting bracket with screws supplied and place cover over connect...

Page 4: ...4019 Phone 540 563 2000 Fax 540 362 9800 www valcom com Sapling WIRELESS WHERE TIMING AND TECHNOLOGY MEET Diagnostic Switch Diagnostic LED Transmit Receive FCC ID R73AMR001 Dependent upon model number...

Page 5: ...highly recommend installing the main transceiver V WMCA before the installation of the Valcom Wireless analog clocks In order to install the clock simply remove the battery cover and install two 2 D...

Page 6: ...scus sion does not correct within 5 minutes press the Transmit Receive button once on the closest clock that has corrected within the past 12 hours clock B for discussion The second hand of clock B wi...

Page 7: ...less clock receives and transmits every minute and in locations where the signal is marginal the likelihood of receiving a signal increases because of the frequent transmission rate What is the advant...

Page 8: ...gnal Then go to the clock that isn t working and press the Transmit Receive switch twice The sec ond hand will go to the twenty 20 second location notifying the user it is looking for the signal This...

Page 9: ...gnostic Switch once which is indi cated by the green LED flashing one 1 time with a one 1 second break A While in diagnostic modes hour and minute hands continue to run normally B The second hand will...

Page 10: ...pon completion of Diagnostic 3 if the Diagnostic LED flashes red the clock requires repair Please contact Valcom Technical Support DIAGNOSTIC 2 This diagnostic will determine the quality of the time s...

Page 11: ...four times with a one 1 second break The second hand will display the battery level by stopping one of the numbers on the clock s face For example If the second hand lands on 2 the battery level 2 2V...

Page 12: ...in a particular installation If this equip ment does cause harmful interference to radio or television reception which can be deter mined by turning the equipment off and on the user is encouraged to...

Reviews: