HANGING INSTRUCTIONS
NOTE: REGULATORS SHOULD ALWAYS BE MOUNTED OUTDOORS. IF
CIRCUMSTANCES FORCE INSTALLING THE REGULATOR INDOORS,
THE REGULATOR'S VENT MUST BE VENTED OUTDOORS USING VENT
LINE NO SMALLER THAN VENT OPENING.
VENT OF REGULATOR MUST
POINT DOWN AND REGULATOR
MUST BE VENTED OUTDOORS
MANUAL SHUT-OFF VALVE
CAN BE INSTALLED BEFORE
THE REGULATOR, UNDER
THE EAVE OF THE BUILDING,
OR AFTER THE REGULATOR
INSIDE THE BUILDING.
OPTIONAL INDOOR
REGULATOR
MOUNTING LOCATION
GAS HOSE
THERMOSTAT
CORD
YOKE
HEATER
THERMOSTAT
1 FT.
BLACK PIPE
THROUGH WALL
VENT LINE
WALL OUTLET
POWER CORD
SEDIMENT
TRAP
W
ALL
CHAIN OR CABLE
1 FT.
1. Assemble according to the illustration below and
tighten all eyebolts securely.
FIG. 2
2. Be sure heater is securely fastened and is hanging
level. (Check crosswise and lengthwise.)
4. See Fig. 3 for typical indoor installation. In any
animal confinement building, consideration must be
given to making sure the heater is located away from
the livestock so that livestock cannot knock the
heater, tear it loose from its mounting, or damage the
heater or its gas supply line in any way. Make sure
you observe and obey minimum clearance distances
to combustible materials as stated in the
specification section of this owner’s manual and on
the heater dataplate.
FIG. 3
SHEET METAL SCREW
4 REQUIRED
DIVERTER
DUCT
DIVERTER
OUTLET SCREWS
TABS BETWEEN SHEET METAL CASE
T AND BLOWER HOUSING. LOOSEN 4
ER OUTLET SCREWS IF NECESSARY.
DIVERTER
DIVERTER
CASE FRONT
OUTLET
SCREWS
DUCT
SHEET METAL SCREW
4 REQUIRED
Alternate Air Diverter Installations
EYEBOLT
NUT
FLAT WASHER
CAGE NUT
CHAIN
CASE TOP
FIG. 1
a. 40,000, 6
60,000, aand 2
225,000 B
BTUH H
Heaters
b. 150,000 B
BTUH H
Heaters