Rev. 1.1
3.Confirming package contents
Item
Q’ty
Main unit
1
AC power cord
*Use appropriate AC power cord conforming to the standards in the country or region where this product used.
(Optional)
Ferrite core clamp filter for AC power cord
*Applicable cable outer diameter 6 to 9mm.
*Attach to AC power cord within 100mm from unit.
1
This operation manual
1
4.Specification
Model
VLP-2430-4
VLP-2460-4
Input Voltage
AC 100 – 240V (rated) ±10% 50/60Hz
Power Consumption
AC100V/1A – AC240V/0.5A
Inrush Current(A) 30/60 (AC115/230V) at cold start
AC Power Cord
3m (max.) cord with a protective earth terminal
Rated output voltage
4 Channels DC24V (between output and GND)
Rated output current
1.1A (Total for 4 channels)
2.2A (Total for 4 channels)
Input Connectors
AC input 3-pin inlet EN 60320-1 certified C14 type x 1
Output Connectors
SMP-03V-BC(JST) 1:output+ 2:NC 3:output-
Insulation resistance:500MΩ(min.) Withstand voltage:AC1500V/minute
External control connectors
Trigger input MIL connector (MIL-C-83503 compliant), 10-pole
For setting the light intensity and lighting mode: e-CON 3-pole
Intensity Control
INT.: Control manually by volume knobs
EXT.: Remote control by external EIA-232-D
Strobe Control
NOR.: The lights are always ON.
STR.: Strobe control.
Lighting method
PWM (100KHz)
Overcurrent protection
Operates at 105% or higher of the rated current
Insulation resistance/ withstand
voltage
Between input and FG (frame ground): AC1500V /minute (10mA), DC500V 50MΩ (min.)
Operating Environment
Temperature: 0 to 40℃ Humidity: 20~85% RH without condensation
Altitude: 2000m Max. Pollution level: 2
Protective ground classⅠ Installation category Ⅱ(restricted to use in indoor
environment)
Storage Temperature/ Humidity
-15 to 40℃/20 to 85% RH without condensation
Cooling Method
Natural air cooling
Dimensions
W120mm x D88mm x H126.5mm
Weight
Approx. 930g
Environmental regulations
RoHS compliant
European Standards
(CE Marking) *Under processing
EN61326-1
EN61010-1