![Val-Tex QS-5000-C Operating Manual Download Page 5](http://html.mh-extra.com/html/val-tex/qs-5000-c/qs-5000-c_operating-manual_849447005.webp)
17. Activate pump by moving the pump control lever to "pump" position (as marked on
pedal). Place a rag under and in front of the bleeder hole on the body bleed
fitting to catch bleeding material. *
DO NOT
place your hand in front of or stand in
front of the bleeder hole. As material passes through the bleeder hole, any
trapped air should vent. Stop the pump when the air is vented.
18. Close the body bleed fitting on the sealant cap.
19. Open the relief valve (319700) on material hose. (|) open (-) close
20. The QS-5000-C is now ready to service your valves.
21. Before removing the coupler from the valve or when the hydraulic pump is not in
use, release the pressure on the hydraulic pump and close relief valve (319700) on
material hose.
22. When the cylinder is empty the pump will begin to stall. Stop the pump. Please
refer to step 1.
* Dispose of any expelled material properly.
Detaching the Lubrication Cylinder
One of the unique features of the QS-5000-C is that you can detach the lubrication
cylinder so one person can load and unload the entire unit.
Note:
Only perform this
procedure when there is no pressure on the cylinder.
1. Disconnect the female hydraulic quick disconnect from the bottom of the lubrication
cylinder.