![Val-Tex QS-5000-C Operating Manual Download Page 3](http://html.mh-extra.com/html/val-tex/qs-5000-c/qs-5000-c_operating-manual_849447003.webp)
QS-5000-C Requirements
A
minimum
of 20 CFM is required to operate the unit. The unit should be run with
100 to 125 PSI input pressure. Exceeding 125 PSI input pressure is not recommended
and could damage the hydraulic pump.
To obtain 10,000 PSI output requires 100 to 125 PSI of input air at 20 CFM.
Moisture separator, oiler, and air line filter (these items are not included) are
recommended on the air supply line to prolong the life of the pump.
If using the Val-Tex #8607 Air Regulator
1. Install 160 psi air gauge (2052L160) in one of the LP ports on the regular.
2. Regulator Specifications:
A. Regulator inlet capacity 3000 psi maximum
B. Output Adjustable 1-160 psi
C. Regulator preset at factory for 100 psi.
One (1) air inlet port is marked HP (High Pressure)
Two (2) air outlet ports are marked LP (Low Pressure)
Before Operating the Pump
1. Remove shipping plug from hydraulic pump and install vent filler cap (20937S)
provided on the opposite end.
2. Remove shipping plug from sealant cap (5001A-1A) and install sealant hose
assembly (5016).