1.
Check that the sensor cables have been cut to a suitable length. The cables must not be looped.
A long cable between units (sensors, transmitters, power supplies, and displays)
can cause a lethal lightning-induced current surge.
WARNING!
If the cables are too long:
a.
Cut the cable to proper length.
b.
If the weather station has rubber flanges, insert the pipette through one of the feed-through
rondels in the flange and pull the cable through.
If the weather station has stainless steel flanges, strip the cables first.
c.
Strip the cable to expose the wires.
~300 [~12]
~15 [0.59]
mm
[in]
1
2
3
4
5
1
Ferrule
2
Unused wires covered with a shrinkable tube or electrical tape
3
Wire
4
Cable shield folded over cable sheath
5
Cable
d.
Connect the cables again. For grounding instructions, see
. For the wiring
diagram, see the installation manual.