set
<parameter>=<value>
Table 23 Parameters for
set
command
Parameter
Mandatory
Description
For the list of
parameters, see
.
Yes
Changes the value of selected parameter.
Example of changing the baud rate:
set
rs485_baud=19200
Example response:
set: rs485_baud=19200
$
For more information, see the full list of CLI parameters.
More information
‣
Configuring Modbus interface (page 20)
‣
Configuring ASCII CSV data sending (page 21)
‣
Changing temperature unit (page 24)
‣
Adjusting linear correction (page 25)
5.9.1 CLI parameters
The following configuration and status parameters are available with AQT530.
Use the parameters with commands
set
and
show
.
Table 24 Modbus interface configuration parameters
Parameter
Type
Range
Default
Unit
Description
rs485_mode
uint8
• 0 = ASCII CSV
• 1 = Modbus ASCII
• 4 = Modbus RTU
4
−
RS-485 mode
rs485_addr
uint8
1 ... 253
1
−
Modbus address (not
used in ASCII CSV
mode)
rs485_baud
uint32
4800 ... 115200
19200
bps
RS-485 baud rate
AQT530 Configuration Guide
M212572EN-C
36