16
Force Program
Force 3 Mode programming steps:
Put switches in appropriate position (CD or MD) for programming according to application guide.
Put ignition switch to “ACC” position.
Wait for long beep followed by a few short beeps. This may take up to one minute.
Put “Both” programming switches in “UP” position, wait for long beep (can take up to 30 seconds)
Put “Right” programming switch in “DOWN” position, wait for beep.
Put “Left” programming switch in “DOWN” position, wait for beep.
Put “Left” programming switch in “UP” position, no beep.
Put “Left” programming switch in “DOWN” position, wait for beep.
Put “Left” programming switch in “UP” position, no beep.
Put “Left” programming switch in “DOWN” position, wait for beep.
Put “Left” programming switch in “UP” position, no beep.
Put “Right” programming switch in “UP” position, wait for long beep.
Put ignition switch to “OFF” position
Wait at least 10 seconds
Put ignition switch into “ACC” or “ON” position.
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
Choose
proper
emulation
mode
(see Installation)
Ignition into
“ACC” or “ON”
position
Ignition into
“OFF” position
Both switches
“UP”
Wait 10 sec
Right
switch
“DOWN”
Wait for short beep
Wait for short beep
Wait for short beep
Wait for long beep
Force 3 Mode Program
Emulation Mode Selection
Right switch
stays “DOWN”
Left switch
“UP”
Both switches
“UP”
Wait for short beep
Right switch
stays “DOWN”
Left switch
“UP”
Right switch
stays “DOWN”
Left switch
“DOWN”
Right switch
stays “DOWN”
Left switch
“DOWN”
Right switch
stays “DOWN”
Left switch
“DOWN”
Wait for short beep
Right switch
stays “DOWN”
Left switch
“UP”
Right switch
stays “DOWN”
Left switch
“DOWN”
Wait up to 30 sec
Long
confirmation beep