background image

0020152779_05 - 10/14 - Vaillant

9

EN

MOUNTING AND INSTALLATION

Caution!
Risk of damage caused by heat 
transfer when soldering.

Heat that is transferred during sol-
dering can cause damage 
(expanded) polypropylene around 
electrical modul and to the seals in 
the service valves.

 

Protect (expanded) polypropylene 
of electrical modul

 

Do not solder the connection 
pieces if the connection pieces 
are screwed to the service valves.

Caution!
Risk of damage due to corrosion.

If plastic pipes that pass oxygen are 
used in the heating installation, this 
may corrode or sludge up the 
appliance’s heating circuit or the 
appliance itself.

 

If you use plastic pipes that pass 
oxygen in the heating installation, 
add a corrosion inhibitor to the cir-
cuit water.

1

2

100

105

1  Installation output 1"

2  Heat pump input 1"

 

Only use the original seals supplied with the appliance.

 

Connect the heating circuit as speci

fi

 ed.

4.4  

Electrical Installation

i

 Notes

The electrical power cable is not supplied with 
the appliance.

Danger!
Risk of electric shock due to an 
improper electrical connection!

Improper electrical connection can 
cause electric shock or might nega-
tively affect the operational safety of 
the product and might cause mate-
rial damage.

 

The electrical connection of the 
product must be carried out only 
by a suitably qualified person.

1

2

30 mm max.

1 Electrical 

wires

2 Insulation

When you connect the electrical wires to a connector on the 
electronic board:

 

Keep a distance of a maximum of 30 mm between 
connector and the start of the insulation. 

 

If using single core wires are used ensure that they are 
wrapped together in an insulating sheath.

 

Fix the cables in the cable-clamp on the Box.

4.4.1 

Connecting the power input (mains 
connection)

The external wiring to be grounded. The polarity must be 
correct and consistent with the standards.

 

Connect the appliance in accordance with the live and 
neutral connections.

The connecting cables between the electrical panel and the 
appliance must be :
- adapted to a 

fi

 xed installation,

- Electrical wires with adapated section linked to the power 
of the appliance.

 

Connect the device to the electrical panel via an 
independent protection system (circuit breaker with a 
separation of at least 3 mm between each contact).

Additional protection may be required during the installation 
to ensure overvoltage category II.

Switching devices from the mains supply must allow 
complete failure of the supply according to the requirements 
of the overvoltage category III.

Component

Supply voltage

(mini section of cable)

Mono supply 
cable

6 kW

230 V (3 x 4 mm²)

4 kW

230 V (3 x 2,5 mm²)

Summary of Contents for VWZ MEH 60

Page 1: ...GB VWZ MEH 60 Installation instructions and instructions for use For the competent person and the operator Installation instructions and instructions for use ...

Page 2: ...number 6 3 3 Data plate description 6 4 Mounting and installation 7 4 1 Preparing the mounting and installation 7 4 2 Mounting the product 8 4 3 Hydraulic installation 8 4 4 Electrical Installation 9 4 5 Cableway and passage 11 5 Start up 12 5 1 Purging the appliance 12 5 2 Installing the casing 13 5 3 Handing over the product to the user 13 6 Repair work 13 6 1 Spare parts 13 6 2 Draining the pro...

Page 3: ...rs 1 4 General safety advices 1 4 1 Danger to life by electric shock Touching live connections can cause serious personal injury Before carrying out any work on the product switch off the power supply Secure the power supply against being switched on again 1 4 2 Danger to life due to missing or not properly working safety devices Missing safety devices can cause life threatening scalding and other...

Page 4: ...tions 1 6 5 1 IMPORTANT Where no British Standards exists materials and equipment should be fit for their purpose and of suitable quality and workmanship The installation of this heating appliance must be carried out by a competent person approved at the time by the Health and Safety Executive and in accordance with the rules in force in the countries of destination Manufacturer s instructions mus...

Page 5: ...e current edition of ETCI rules The heating appliance MUST be connected to a permanent 230V ac 50Hz supply Connection of the whole electrical system of the heating appliance including any heating controls to the electrical supply MUST be through one common isolator and must be fused 30 Amp maximum Isolation should be by a double pole switched fused spur box with a minimum gap of 3mm for both poles...

Page 6: ...ucture 3 1 1 Electrical Module 1 A B 1 Temperature Sensor pocket A Heat input from the heat pump B Heat outlet towards the installation 3 2 Type designation and serial number Data plate location 1 1 Data plate The type designation and the serial number are shown on the data plate 3 3 Data plate description The data plate certifies the country where the product is intended to be installed The data ...

Page 7: ...ting clearances 4 1 2 1 Product and connection dimensions 452 140 140 87 101 447 40 50 50 4 1 2 2 Distance to inflammable parts Make sure that no item that can easily catch fire is in direct contact with the components which may reach a temperature greater than 80 C Make sure that there is a minimum distance of 200 mm between items that can easily catch fire and the hot surfaces 4 1 2 3 Mounting c...

Page 8: ...ht of the product 4 2 Mounting the product 4 2 1 Removing the casing 1 1 Front casing Remove the front casing 1 4 2 2 Wall mounting of the product a Danger Danger to life if the load bearing capacity of the fixing elements used is insufficient If the fixing elements do not have suf ficient load bearing capacity the prod uct can come loose and fall down When fitting the product ensure that the fixi...

Page 9: ...might cause mate rial damage The electrical connection of the product must be carried out only by a suitably qualified person 1 2 30 mm max 1 Electrical wires 2 Insulation When you connect the electrical wires to a connector on the electronic board Keep a distance of a maximum of 30 mm between connector and the start of the insulation If using single core wires are used ensure that they are wrappe...

Page 10: ... mains voltages higher than 400 V electronic components may be destroyed Make sure that the rated voltage of the mains is 400 V Connect alimentation cables of product on the electrical panel of installation 4 4 1 1 Method of collection of electrical cables C A B 4 4 1 2 230 V connection Cable routing 6 kW b Caution Comply with the instructions on the label affixed inside the electri cal casing 02 ...

Page 11: ...Command relay connection 4 4 2 1 With 2 kW electrical booster N N 1 L2 L1 L3 2 1 2 4 4 2 2 With 4 kW electrical booster N N 1 2 L2 L1 L3 1 2 4 4 2 3 With 6 kW electrical booster N N 1 2 L2 L1 L3 1 2 3 4 4 2 4 With multi stage booster N N 1 2 L2 L1 L3 1 2 4kW 2kW 1 Electrical booster module 2 Towards command relay 3 Electrical shunt 4 5 Cableway and passage i Notes The cables must pass through the ...

Page 12: ...t transfer 5 Start up For filling refer to the installation instructions of the heat pump Check the electrical and water installation Check all connections for leaks Fill the heating installation Purge your heating system Replace the power e Danger Risk of death from electric shock Before carrying out the following work ensure that the product has been disconnected from the power supply 5 1 Purgin...

Page 13: ...oduct in the course of the CE conformity check If you do not use certified genuine Vaillant spare parts during maintenance or repair the CE conformity of the product will expire That is why we imperatively recommend to install genuine Vaillant spare parts 6 2 Draining the product b Caution Risk of material damage Avoid all risk of water projection onto the electrical components 2 1 1 Air vent 2 Dr...

Page 14: ...Recycling and disposal The competent person who installed your product is responsible for the disposal of the packaging If the product is identified with this symbol In this case do not dispose of the product with household waste Instead hand in the product to a collection centre for old electrical or electronic appliances If the product contains batteries that are marked with this symbol these ba...

Page 15: ......

Page 16: ...ingham Road Belper Derbyshire DE56 1JT Telephone 0330 100 3461 Vaillant Service Solutions 0330 100 3461 Spares Technical Enquiries 017 73 59 66 15 info vaillant co uk Spares Technical Enquiries technicalspares groupservice co uk www vaillant co uk These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufacturer s written consent ...

Reviews: