Vaillant VRC 700f/4 Operating Instructions Manual Download Page 18

5 Operating and display functions

18

Operating instructions 0020237621_02

Day

: The operating mode constantly controls the exchange

of air using the value that you set in the

Max. vent. stage:

Day

ventilation level.

Set-back

: The operating mode constantly controls the ex-

change of air using the value that you set in the

Max. vent.

stge: Night

ventilation level.

5.3.4

Setting the operating mode for domestic
hot water generation

Op. mode

Domestic hot water

You can use this function to specify how the heating in-
stallation should operate during domestic hot water gen-
eration.

off

: Domestic hot water generation is switched off and the

frost protection function is activated.

Auto

: The operating mode brings the domestic hot water

generation to the desired temperature set for

Domestic hot

water

in the time periods that you have set in the time pro-

gramme.

Day

: The operating mode brings the domestic hot water gen-

eration to the desired temperature set for

Domestic hot wa-

ter

, regardless of the time periods that you have set in the

time programme.

5.3.5

Operating mode for circulation

The operating mode for circulation always corresponds to
the operating mode for hot water. You cannot set a different
operating mode.

5.4

Advanced functions

The advanced functions can be activated directly from any
operating mode using the right-hand selection button

Op.

mode

. If the heating installation is equipped with more than

one zone, the activated advanced function only applies for
the zone that was preset by the competent person.

If more than one zone is activated, you can set a separate
advanced function for each zone using the left-hand selec-
tion button

Menu

Basic settings

.

The path details given at the start of each advanced function
description indicate how you can access this advanced func-
tion in the menu structure.

5.4.1

Activating manual cooling

Op. mode

Manual cooling

If the outdoor temperature is high, you can activate the

Manual cooling

advanced function. You define for how

many days you want to activate the advanced function. If
you activate

Manual cooling

, you cannot use the heating

function at the same time. The

Manual cooling

function

takes priority over the heating function.

The setting applies for as long as the advanced function is
active. The advanced function is deactivated if the days that
are set have elapsed or if the outdoor temperature falls be-
low 4 °C.

If you want to set the temperature separately for more than
one zone, you can set these temperatures using the

Desired

temperatures

function.

5.4.2

Activating 1 day at home

Op. mode

1 day at home

Menu

Basic settings

Operating mode

ZONE1

1

day at home

The

1 day at home

advanced function activates the

automatic mode in the operating mode

Heating

with the

settings for the

Sunday

.

The advanced function is automatically deactivated after
00:00 (midnight) or you can cancel the advanced function
first. The heating installation then returns to the pre-set oper-
ating mode.

5.4.3

Activating 1 day away from home

Op. mode

1 day away from home

Menu

Basic settings

Operating mode

ZONE1

1

day away from home

The

1 day away from home

advanced function brings

the room temperature to the desired

Set-back

temperat-

ure.

Domestic hot water generation and circulation are switched
off and the frost protection is activated.

Ventilation is activated and works at the lowest ventilation
level.

The advanced function is automatically deactivated after
00:00 (midnight) or you can cancel the advanced function
first. The heating installation then returns to the pre-set oper-
ating mode.

5.4.4

Activating Ventilation boost

Op. mode

Ventilation boost

Menu

Basic settings

Operating mode

ZONE1

Ventilation boost

This

Ventilation boost

advanced function switches the

zone off for 30 minutes.

The frost protection function is activated, and domestic hot
water generation and circulation remain active.

Ventilation is activated and works at the highest ventilation
level.

The advanced function is automatically deactivated after 30
minutes or you can cancel the advanced function first. The
heating installation will then return to the pre-set operating
mode.

5.4.5

Activating Party function

Op. mode

Party function

Menu

Basic settings

Operating mode

ZONE1

Party function

The advanced function regulates the room temperature
to the desired

Day

temperature, the domestic hot water

to the desired

Domestic hot water

temperature and the

ventilation to ventilation level

Max. vent. stage: Day

in

accordance with the set time periods. The circulation is
activated.

The advanced function is automatically deactivated after six
hours or you can cancel the advanced function first. The
heating installation will then return to the pre-set operating
mode.

Summary of Contents for VRC 700f/4

Page 1: ...instructions Weather compensated sys tem control VRC 700f 4 GB IE Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vaillant de www v...

Page 2: ...ating structure 7 4 2 Basic display 8 4 3 Operating concept 8 5 Operating and display functions 10 5 1 Information 11 5 2 Settings 13 5 3 Operating modes 17 5 4 Advanced functions 18 5 5 Messages 19 6...

Page 3: ...ervision or instruc tion concerning use of the product in a safe way and understand the hazards involved Children must not play with the product Cleaning and user maintenance work must not be carried...

Page 4: ...1 Safety 4 Operating instructions 0020237621_02 If you cannot ensure the operation have a competent person drain the heating install ation...

Page 5: ...700f 4 wireless system control Remote control This refers to the VR 91f wireless remote control Outdoor temperature sensor This refers to the wireless outdoor temperature sensor 2 5 Function availabil...

Page 6: ...stem control If the temperature lies below the set value the system control increases the temperature in the domestic hot water circuit and therefore heats up the wa ter to the set domestic hot water...

Page 7: ...tated on the data plate The manufacturer hereby declares that the type of radio equipment that is described in these instructions complies with Directive 2014 53 EU The complete text for the EU De cla...

Page 8: ...stallation is designed for two of the three operating modes heating cooling or ventilating you can switch the basic display to the required operating mode Setting the preferred display Page 16 4 2 3 I...

Page 9: ...ct Auto On Switch to another display view with the request Permanent change to the Day temp heating Change to the Day temp heating for six hours Off Direct change to the Set back temp heat for six hou...

Page 10: ...me Date time Display Back Select 6 Press the right hand selection button Select The system control switches to setting level Display The adjustable value for the Display contrast is highlighted Displa...

Page 11: ...solar yield to 0 kWh Menu Information System status Environmental yield You can use this function to read the total environment yield Note the contents of the section Display for energy con sumption a...

Page 12: ...se this function to read the total electrical con sumption for hot water in the current month Menu Information Consumption Current month Hot water Fuel You can use this function to read the total fuel...

Page 13: ...temperature in the living rooms Set back temp heat Set a low room temperature at which the living rooms do not cool down Cooling Day temp cooling Set a comfortable room temperature in the living rooms...

Page 14: ...display and change the set times for the block marked with 5 2 3 4 Setting the Heating time programme Menu Time programmes ZONE1 The time programmes are only effective for the Heat ing operating mode...

Page 15: ...mode 5 2 6 Select language Menu Basic settings Language You can use this function to change to the language that you want to appear in the display 5 2 6 1 Setting your language 1 Press the left hand s...

Page 16: ...example 5 2 12 2 Setting the low tariff electricity rate Menu Basic settings Costs Low tariff elec rate The hybrid manager can use this function to correctly calculate the costs for the back up boiler...

Page 17: ...the system control regulates the control behaviour set by the competent person Eco The heating function is switched off and the system control monitors the outdoor temperature If the outdoor temperatu...

Page 18: ...on is active The advanced function is deactivated if the days that are set have elapsed or if the outdoor temperature falls be low 4 C If you want to set the temperature separately for more than one z...

Page 19: ...ting installation the setting level displays the value Fault list The right hand selection button has been assigned the Display function 6 Troubleshooting Overview of fault messages Appendix B 6 1 Imp...

Page 20: ...a damp cloth and a little solvent free soap Do not use sprays scouring agents detergents solvents or cleaning agents that contain chlorine 8 Decommissioning 8 1 Decommissioning the product If you wan...

Page 21: ...ervice Solutions 9 2 Customer service To ensure regular servicing it is strongly recommended that arrangements are made for a Maintenance Agreement Please contact Vaillant Service Solutions for furthe...

Page 22: ...user level The description of the functions for ZONE1 also applies for all available zones Setting level Values Unit Increment select Default setting Min Max Information System status System Fault st...

Page 23: ...month Heating Electricity Total value for the last month kWh Fuel Total value for the last month kWh Hot water Electricity Total value since start up kWh Fuel Total value since start up kWh Informatio...

Page 24: ...1 Depending on the ventilation unit Max vent stge Night Depending on the ventilation unit 1 Depending on the ventilation unit Time programmes ZONE1 Heating Time programmes ZONE1 Cooling Time programme...

Page 25: ...12 99 dd mm yy Day Month Year 01 01 14 End 01 01 01 31 12 99 dd mm yy Day Month Year 01 01 14 Temperature 5 30 1 15 Days at home scheduling Start 01 01 01 31 12 99 dd mm yy Day Month Year 01 01 14 En...

Page 26: ...1 Take all the batteries out 2 Insert the batteries in the battery compartment making sure that the poles are the right way round 3 If the fault persists inform the competent person Display view No R...

Page 27: ...rator 1 is an example of a maintenance message that may appear for heat generators 1 to 6 Message Description Maintenance work Interval 1 Service heat pump 1 The heat pump requires main tenance work R...

Page 28: ...ing concept 8 Operating level 7 Operating mode 17 Operating mode in the basic display 8 Outdoor temperature setting the offset 16 P Party 18 Preventing a malfunction 7 R Reading the article number 7 1...

Page 29: ...tructions 29 System OFF 19 System status 11 T Time period deviating times in the block 14 Time programme 13 quick setting 14 Setting 14 V Ventilation 6 Ventilation boost 18 Ventilation level 13 Z Zone...

Page 30: ......

Page 31: ......

Page 32: ...e DE56 1JT Telephone 0330 100 3461 info vaillant co uk www vaillant co uk These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufacturer...

Reviews: